Dräger Zeus Anesthesia Workstation EUVDEUVD-2025-210044

| CVE-2025-15653 HIGH
Exposure of Resource to Wrong Sphere (CWE-668)
2026-06-02 VulnCheck GHSA-qw79-r33f-9pvj
7.0
CVSS 4.0 · Vendor: VulnCheck
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Recon
    Gain physical access to OR/workstation
  2. Delivery
    Insert malicious USB device into Zeus IE/RS C500 port
  3. Exploit
    Abuse unrestricted USB interface (CWE-668)
  4. Install
    Manipulate therapy software or device-processed data
  5. C2
    Establish foothold on workstation
  6. Execute
    Pivot via network or Dräger Service Connect
  7. Impact
    Impact patient safety or hospital network

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V8 - Authorization Resource sphere isolation
MITRE ATT&CK

1 technique across 1 tactic: Collection

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Exploitation requires physical access to a USB port on a Dräger Zeus Infinity Empowered (Zeus IE) or Zeus RS C500 anesthesia workstation - typically meaning attacker presence in the operating room, post-anesthesia care area, or storage space where the device sits - combined with the device being powered on and the USB interface unprotected by port blockers, kiosk lockdown, or operator supervision. CVSS 4.0 specifies AV:P (Physical) and PR:N/UI:N, so no credentials and no operator interaction at the device console are required once an attacker can reach the port. Pivot to broader networks additionally requires the workstation to be connected to a hospital network or to Dräger Service Connect at the time of compromise; air-gapped or standalone deployments limit impact to the device itself. Remote, network-based exploitation is not possible.

Impact

The CVSS 4.0 vector AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H clearly bounds this as a physical-access attack with high confidentiality, integrity, and availability impact on the vulnerable system but no scope change (SC:N/SI:N/SA:N) - meaning the CVSS model itself does not credit the described network-pivot consequence. EPSS data was not provided and the CVE is not on CISA KEV, with no POC published, so by quantitative signals this is not a mass-exploitation priority. However, the qualitative risk is meaningfully higher than the 7.0 score suggests because (a) the targets are life-critical medical devices where integrity loss can directly harm patients, (b) operating-room environments routinely admit USB drives for clinical engineering and updates, and (c) the description explicitly notes the device can be used as a network pivot, a downstream consequence CVSS 4.0 does not score here. The mismatch between the description's network-pivot claim and the SC:N/SI:N/SA:N subsequent-system metrics should be verified with Dräger before deciding whether to treat this as a contained device flaw or a beachhead risk to hospital networks.

Exploit ScenarioDerived

An insider, contracted vendor, or intruder with brief unsupervised access to the anesthesia workstation between procedures inserts a malicious USB device - a mass-storage drive carrying tampered configuration, or a HID/peripheral emulator - into an unprotected port on the Zeus IE or Zeus RS C500. The device then accepts the manipulated input, allowing the attacker to alter therapy parameters, exfiltrate or corrupt patient data processed by the workstation, and, if the device is networked to hospital infrastructure or Dräger Service Connect, use the foothold to reach upstream systems. No public exploit is identified at time of analysis, so any active attempt would likely require attacker-developed tooling.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
Patch available 0.0% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv3 – Jun 02, 2026

Physical USB tampering against Dräger Zeus Infinity Empowered (Zeus IE) and Zeus RS C500 anesthesia workstations allows an attacker with bedside access to compromise software integrity, alter therapy data, and pivot to connected networks or Dräger Service Connect. The flaw, disclosed by VulnCheck and tracked under CWE-668 (Exposure of Resource to Wrong Sphere), carries a CVSS 4.0 base score of 7.0 reflecting high impact across confidentiality, integrity, and availability of the device itself. There is no public exploit identified at time of analysis and no CISA KEV listing, but the medical-device context elevates patient-safety concern even at moderate technical severity.

Earlier versions of this analysis (2)
v2 Jun 02, 2026 - 22:28 cvss changed CVSS 7.0

Physical USB tampering against Dräger Zeus Infinity Empowered (Zeus IE) and Zeus RS C500 anesthesia workstations allows an attacker with bedside access to subvert software integrity, alter therapy-related data, and potentially pivot to connected hospital networks or Dräger Service Connect. The flaw was disclosed by VulnCheck and carries a CVSS 4.0 score of 7.0 (AV:P) reflecting the physical-access prerequisite; no public exploit identified at time of analysis and the issue is not listed in CISA KEV.

v1 Jun 02, 2026 - 22:00 CVSS 6.8

Physical USB interface exploitation on Dräger Zeus IE (Zeus Infinity Empowered) and Zeus RS C500 anesthesia workstations enables unauthenticated local attackers to compromise software integrity, impair therapy delivery, and manipulate device-processed data. The CVSS vector (AV:P/AC:L/PR:N/UI:N) confirms physical presence is required but no credentials are needed, with all three impact axes (C/I/A) rated High. Critically, when the workstation is connected to a hospital network or Dräger Service Connect, the compromised device can serve as a pivot point for broader network-based attacks against clinical infrastructure. No public exploit identified at time of analysis.

RemediationAI

No vendor-released patch version is identified at time of analysis; healthcare providers should consult the Dräger security portal at https://www.draeger.com/security and the VulnCheck advisory at https://www.vulncheck.com/advisories/dr-ger-zeus-ie-anesthesia-workstation-usb-interface-privilege-escalation for any updated firmware or service bulletins, and contact Dräger Service Connect support to confirm the fix train. As compensating controls, physically restrict access to Zeus IE and Zeus RS C500 USB ports using port-blockers or tamper-evident seals during clinical use (trade-off: clinical engineering must remove them for legitimate service), enforce chaperoned access to operating rooms when devices are unattended, segment the workstations onto an isolated biomedical VLAN with egress filtering so a compromised device cannot pivot laterally (trade-off: may complicate Dräger Service Connect telemetry - coordinate firewall exceptions with the vendor), and require biomedical engineering to approve and scan any USB media before connection.

Affected VersionsENISA

Zeus IE 0 <1.0.5
Zeus RS C500 0 <1.0.9

Affected Packages

euvd zeus_ie fix: 1.0.5
euvd zeus_rs_c500 fix: 1.0.9

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 2 packages in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The Zeus IE and Zeus RS C500 are network-connected anesthesia delivery workstations used in operating theaters; the CPE strings cpe:2.3:a:dräger:zeus_ie and cpe:2.3:a:dräger:zeus_rs_c500 (all versions wildcarded) indicate the vulnerability spans the affected product lines without a known fixed build identifier in the public record. CWE-668 describes a resource - here the device's USB ports and the software/firmware surface they expose - being made accessible to an actor (anyone physically at the device) who should not be able to reach it. In practice the USB stack on these workstations lacks adequate authentication, signing, or input validation, so peripherals or storage devices can deliver code, configuration changes, or malformed data that the underlying anesthesia control software trusts.

Know when Zeus Ie gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (VulnCheck) PRIMARY 7.0 HIGH
CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (VulnCheck) · only source for this CVE.

CVSS VectorVendor: VulnCheck

Attack Vector
Physical
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

5
Patch available
Jun 02, 2026 - 23:01 EUVD
Analysis Updated
Jun 02, 2026 - 22:28 vuln.today
v3 - CVSS changed
Analysis Updated
Jun 02, 2026 - 22:28 vuln.today
v2 - CVSS changed
Severity Changed
Jun 02, 2026 - 22:22 NVD
MEDIUM HIGH
CVSS changed
Jun 02, 2026 - 22:22 NVD
6.8 (MEDIUM) 7.0 (HIGH)

DescriptionCVE.org

Dräger Zeus Infinity Empowered (Zeus IE) and Zeus RS C500 anesthesia workstations contain a local security vulnerability that allows unauthorized individuals with physical access to compromise software integrity via USB interface manipulation. Attackers can exploit the unprotected USB interfaces to impair therapy functions, manipulate device-processed data, or leverage the device as a pivot point for broader network-based attacks when connected to a network or Dräger Service Connect.

Executive ViewAI

Why It Matters

Dräger Zeus anesthesia workstations (Infinity Empowered and RS C500 models) are vulnerable to physical USB tampering allowing bedside attackers to compromise device software integrity and alter patient therapy data without authentication, with no vendor patch currently available. This vulnerability poses direct patient safety and regulatory compliance risks in healthcare organizations, including potential lateral movement into connected clinical networks and Dräger Service Connect infrastructure.

Business Impact: High
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations include: (1) Physical access restriction-implement cable locks, protective enclosures, or restricted zones limiting bedside access to credentialed clinical staff; (2) USB hardening-disable USB ports via BIOS/firmware where clinically feasible, or deploy USB port locks and physical covers; (3) Network isolation-segment anesthesia devices to protected network with restricted egress; prohibit internet and untrusted network connectivity; (4) Device monitoring-audit logs for unauthorized configuration or firmware modifications; alert on suspicious device activity; (5) Service access controls-require VPN authentication and approval workflows for all Dräger Service Connect remote sessions; implement connection time limits; (6) Incident procedures-develop detection and response protocols for suspected physical tampering or integrity compromise.

Threat Intelligence Overview

EPSS Score
0.0%
Top 94% exploitable
Data Quality
6 sources
Confidence: High

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.0%
Patch available Yes
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Small
Automatable
No
Human Impact
High
Technical Impact
Total

Priority Score

35
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +35
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.