Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessGain read access to application logs/diagnostics
-
DeliveryTrigger or locate HTTP error exception message
-
ExploitExtract plaintext PLC restore password
-
ExecutionAuthenticate to SIMATIC S7 PLC
-
ImpactPerform unauthorized restore/config operations
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A10:2025 - Mishandling of Exceptional Conditions
ASVS 5.0
V16 - Security Logging and Error Handling Error message sanitization
MITRE ATT&CK
1 technique across 1 tactic: Discovery The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Exploitation requires that the vulnerable .NET Client Library (all versions below V3.3.62) has actually handled a PLC restore operation that produced an HTTP error/exception, AND that the attacker can read the resulting logs, exception traces, or diagnostic output where the restore password is written in plaintext. Limiting factors: the attacker needs pre-existing low-privilege local access to those logs or diagnostic artifacts (PR:L, AV:L) - the flaw does not grant that access; a restore workflow must have been exercised and failed/errored to generate the message; and the leaked secret is useful only against the corresponding SIMATIC S7 PLC. There is no user interaction requirement and no special PLC-side configuration beyond using the affected library version. |
| Impact | This is a moderate, defense-in-depth issue rather than a front-line priority. The CVSS 3.1 vector (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N, base 5.5) describes a local, low-privilege information-disclosure flaw with high confidentiality impact but no integrity or availability impact - consistent with CWE-209 (Generation of Error Message Containing Sensitive Information). No EPSS score, CISA KEV listing, or public POC was supplied in the intelligence, so there is no public exploit identified at time of analysis and no evidence of active exploitation. The real-world risk is bounded by the prerequisite that an attacker must already have access to logs or diagnostic output containing the leaked PLC restore password; the vulnerability does not itself grant that access, making it a privilege-escalation/secondary-exposure concern rather than a standalone remote threat. Note one tension to verify: the description frames the leak as appearing in 'HTTP error exception messages,' which could suggest a network-facing surface, yet the CVSS vector is AV:L - Siemens evidently scored the exploitation point as consumption of local logs/diagnostic output rather than over-the-wire interception, which is the more conservative and defensible reading given the client-library context. |
| Exploit ScenarioDerived | An attacker or malicious insider with read access to application logs, crash dumps, or diagnostic output produced by software using the .NET Client Library locates an unredacted plaintext PLC restore password captured in an HTTP error/exception message. They reuse that password to authenticate to the SIMATIC S7 PLC and perform unauthorized restore or configuration operations. No public exploit code is required - the attack is simply reading an exposed secret from logs. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 13, 2026
The .NET Client Library for SIMATIC S7 Webserver API (all versions before V3.3.62) fails to redact PLC restore passwords from HTTP error exception messages, causing plaintext credentials to be written into logs and diagnostic output. An authenticated attacker with low-privileged local access to those logs (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N, base score 5.5) can recover the restore password and, if it is still valid, use it to perform unauthorized restore or configuration operations against the corresponding SIMATIC S7 PLC. Exploitation is conditional: the vulnerable library must have handled a restore operation that produced an HTTP error, and the resulting diagnostic artifact must be readable by the attacker. No public exploit code has been identified at time of analysis and this CVE has not been confirmed actively exploited (CISA KEV); Siemens has released a fix in V3.3.62.
RemediationAI
Upgrade the .NET Client Library for SIMATIC S7 Webserver API to V3.3.62 or later, the vendor-released fix, and redeploy every application that references it; consult Siemens Security Advisory SSA-390352 (https://cert-portal.siemens.com/productcert/html/ssa-390352.html) for the definitive version and product list. Until the upgrade is deployed, treat any log or diagnostic artifact containing a failed restore attempt as a credential-bearing secret: restrict filesystem ACLs on client-library log directories to the service account only, exclude these paths from broadly readable support bundles, and apply masking/filtering rules in the log pipeline (for example regular expressions that strip restore-password fields) so the plaintext secret is not forwarded to SIEM collectors or long-term storage - the trade-off is loss of some troubleshooting fidelity and possible regex maintenance as message formats change. Reduce client-library logging verbosity or disable exception-detail logging for restore operations to prevent the secret from being emitted in the first place, accepting reduced diagnostic capability for restore failures. Rotate the PLC restore password after any failed restore attempt that generated an affected error message, and prefer one-time or short-lived restore credentials so a leaked value has little residual value; this requires coordination with PLC operations and may involve a maintenance window. Finally, limit read access to log repositories and diagnostic shares to only those users who need it, since PR:L local log access is the prerequisite the flaw depends on.
Affected VersionsENISA
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The affected component is the Siemens .NET Client Library for the SIMATIC S7 Webserver API, used by engineering and integration applications to talk to the embedded webserver on S7 PLCs. The root cause is CWE-209 (Generation of Error Message Containing Sensitive Information): when a PLC restore request fails, the exception/HTTP error object returned by the library embeds the request payload - including the restore password - verbatim, and that text is subsequently serialized into log files, stack traces, or other diagnostic output rather than being masked. This is a client-side information-handling defect, not a PLC firmware flaw, so the exposure surface is wherever applications built on this library run and wherever their logs are stored or shipped (local files, SIEM/collectors, support bundles). The CPE entry cpe:2.3:a:siemens:.net_client_library_for_simatic_s7_webserver_api:*:*:*:*:*:*:*:* matches every build below V3.3.62. Because the CVSS vector is AV:L/PR:L/UI:N, the attacker must already hold local low-privilege access to the log or diagnostic artifact; the library does not grant that access, and the leaked secret is only useful against the specific PLC whose restore workflow generated it.
Know when Net Client Library For Simatic S7 Webserver Api gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
Secret is read from local logs/diagnostic output requiring low-privilege local access (AV:L/PR:L); high confidentiality loss of a plaintext password, with no direct integrity or availability impact from the disclosure itself.
Primary rating from Vendor (siemens).
CVSS VectorVendor: siemens
Lifecycle Timeline
1DescriptionCVE.org
A vulnerability has been identified in .NET Client Library for SIMATIC S7 Webserver API (All versions < V3.3.62). Affected applications do not properly redact PLC restore passwords from HTTP error exception messages.
This could allow an attacker with access to logs or other diagnostic output to obtain the plaintext restore password and potentially perform unauthorized operations on the PLC.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
EUVD-2026-98393
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB