Skip to main content

Contec CAN-2 CVE-2026-82793

| EUVDEUVD-2026-77249 HIGH
Unrestricted Upload of File with Dangerous Type (CWE-434)
2026-09-14 jpcert GHSA-463x-vp7x-ppgq
8.6
CVSS 4.0 · Vendor: jpcert
Share

Severity by source

Vendor (jpcert) PRIMARY
8.6 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
vuln.today AI
7.2 HIGH

Network-reachable upload, low complexity, but PR:H required per CVSS 4.0 source; full C/I/A on device, scope unchanged.

3.1 AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (jpcert).

CVSS VectorVendor: jpcert

Attack Vector
Network
Attack Complexity
Low
Privileges Required
High
User Interaction
None
Scope
X

Lifecycle Timeline

4
Patch available
Sep 14, 2026 - 08:01 EUVD
Analysis Generated
Sep 14, 2026 - 07:25 vuln.today
CVSS changed
Sep 14, 2026 - 07:22 NVD
7.2 (HIGH) 8.6 (HIGH)
CVE Published
Sep 14, 2026 - 06:45 cve.org
HIGH 8.6

DescriptionCVE.org

Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If a specially crafted file is uploaded by a remote authenticated attacker, arbitrary code may be executed on the product.

AnalysisAI

Arbitrary code execution is possible on Contec CAN 2.0B series communication converter units (CAN-2-WF wireless LAN and CAN-2-USB USB variants) via unrestricted file upload. A remote attacker holding high-privilege credentials can upload a specially crafted file to the device's web interface, resulting in code execution directly on the embedded unit. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
technique details hidden
Delivery
technique details hidden
Exploit
technique details hidden
Execution
technique details hidden
Impact
technique details hidden

Vulnerability AssessmentAI

Exploitation Exploitation requires remote network access to the device management web interface AND authentication with high-privilege (administrator-level) credentials (PR:H per CVSS 4.0 vector). … Additional conditions and limiting factors are described in the full assessment.
Risk Assessment The CVSS 4.0 base score of 8.6 with vector AV:N/AC:L/AT:N/PR:H/UI:N reflects network-reachable exploitation with no complexity or interaction requirements, but critically gated by PR:H (high privilege). … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario Full exploit scenario with step-by-step reproduction available after sign-in.
Remediation Consult the Contec vendor security advisory (contec_security_ph_26091000_en.pdf linked above) and the JPCERT/CC advisory JVNVU90314828 for the specific patched firmware version and update procedure; apply any available firmware update immediately. … Detailed patch versions, workarounds, and compensating controls in full report.

Recommended ActionAI

Within 24 hours: Inventory all Contec CAN 2.0B devices across your organization and document current firmware versions and network locations. …

Sign in for detailed remediation steps and compensating controls.

Threat intelligence, references, and detailed analysis are available after sign-in.

Share

CVE-2026-82793 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy