EasyIO FS32 CVE-2026-71448

| EUVDEUVD-2026-91068 MEDIUM
Initialization of a Resource with an Insecure Default (CWE-1188)
2026-10-01 jci GHSA-5w6q-pfff-cwc7
5.6
CVSS 4.0 · Vendor: jci
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Gain adjacent-network foothold with elevated access
  2. Delivery
    Satisfy required attack precondition
  3. Exploit
    Abuse insecure default initialization to bypass auth
  4. Execution
    Alter controller config/logic
  5. Impact
    Compromise integrity and availability of building systems

Vulnerability Assessment

Weakness
CWE
ASVS 5.0
V13 - Configuration Secure default settings
Exploitation Conditions

Exploitation requires an insecurely-initialized default resource on the EasyIO FS32 controller to be present (the condition inherent to this insecure-default-initialization flaw, affecting versions before 3.0b63). Limiting factors are significant: the attacker must be on the adjacent/local network (AV:A - not remotely internet-exploitable), must already possess high privileges (PR:H - authenticated/privileged access), must overcome high attack complexity (AC:H), and must meet a specific attack requirement (AT:P). These combined gates mean this is realistically exploitable only by an attacker who already has a privileged position on the building-automation network, not by an unauthenticated remote actor.

Impact

This is a MEDIUM-severity issue (CVSS 4.0 base 5.6) whose real-world risk is meaningfully constrained by its exploitation preconditions rather than its impact. The vector CVSS:4.0/AV:A/AC:H/AT:P/PR:H shows that an attacker needs adjacent-network access (not internet-routable), must already hold high privileges, must overcome high attack complexity, AND satisfy a specific attack requirement (AT:P) - four independent gates that collectively make opportunistic or mass exploitation unlikely. Offsetting that, the impact is severe once those gates are passed: VI:H/VA:H plus subsequent-system impacts SC:H/SI:H/SA:H indicate an attacker can compromise integrity and availability of both the device and downstream systems, which for a building-automation controller can mean manipulation of physical HVAC/control processes. The E:P maturity flag indicates a proof-of-concept exists, so publicly available exploit code likely exists, but there is NO CISA KEV listing and no EPSS value provided, so there is no evidence of widespread active exploitation - this reads as a credible but gated, likely-targeted risk rather than a wormable or internet-wide threat. One point to verify: the tag labels this 'Information Disclosure,' yet the CVSS confidentiality impact is only Low (VC:L) while integrity/availability are High - the tag appears inconsistent with the scored impact and the CWE-1188 authentication-abuse framing.

Exploit ScenarioDerived

An attacker who has gained a foothold on the same adjacent network segment (e.g., an insider or a compromised device on the building network) and who already holds elevated access abuses an insecurely-initialized default resource/credential to bypass intended authentication controls on the EasyIO FS32 controller. Having defeated authentication, they tamper with control logic or configuration, affecting the integrity and availability of the controller and connected building systems. A proof-of-concept is indicated by the CVSS E:P maturity flag, though exploitation requires satisfying the high-complexity attack requirement.

This Month Plan within 30 days. Why: MEDIUM severity (CVSS 4.0-6.9).
Patch available 0.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Oct 01, 2026

Authentication abuse in Johnson Controls EasyIO FS32 building-automation controllers running firmware earlier than 3.0b63 lets an attacker who already holds privileged access on the adjacent network leverage an insecurely initialized default resource to subvert authentication, with assessed consequences spanning integrity and availability of the controller and knock-on effects at system scope. Exploitation is heavily gated: the attacker must sit on the adjacent/local network (AV:A, not internet-reachable), must already be privileged (PR:H), must clear high attack complexity (AC:H) and a specific attack requirement (AT:P), so this is realistically reachable only by someone with an existing foothold on the building-automation network, not by an unauthenticated remote actor. No public exploit code and no confirmed active exploitation were identified at time of analysis, and the CVSS 4.0 base score is 5.6 (medium).

RemediationAI

Vendor-released patch: upgrade EasyIO FS32 firmware to 3.0b63 or later, which is the version boundary given in the advisory, and follow the Johnson Controls Trust Center security advisory page (https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories) for the exact update package and any controller-specific installation steps; re-initialize any default credentials, keys, or onboarding artefacts after flashing rather than carrying them forward, since the root cause is insecure default initialization and a firmware upgrade alone may not rotate already-exposed values. Until every unit is updated, apply compensating controls with their trade-offs understood: place FS32 controllers on an isolated building-automation VLAN with strict ACLs so that only the engineering workstations that genuinely need access can reach them, accepting that this restricts remote maintenance and requires disciplined firewall upkeep; never expose the controller management interface to the internet or to flat corporate networks, which removes the adjacent-network (AV:A) foothold the flaw depends on but can complicate vendor remote support; rotate all factory-default and shared credentials, which may break existing BMS integrations that rely on the old values and should be coordinated with the integrator; and disable unused services or commissioning interfaces on the controller, accepting reduced functionality during setup windows. Given the AT:P attack-requirement and AC:H complexity gates, prioritize patching controllers that are reachable from segments shared with non-BAS hosts or that have elevated privileges granted to multiple accounts, and monitor for unexpected authentication events or configuration changes on these devices as a detection backstop.

Affected VersionsENISA

EasyIO FS32 0 <3.0b63

Affected Packages

euvd easyio_fs32 fix: 3.0b63

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The root cause is CWE-1188 (Insecure Default Initialization of Resource): the EasyIO FS32 controller ships with or falls back to a default-initialized resource - the classic patterns being factory-default credentials, embedded or shared keys, or an authentication artefact that is generated predictably rather than uniquely per device. Because that resource is never re-initialized securely, an attacker who can reach the device from an adjacent network segment with sufficient privilege can abuse the authentication path instead of breaking cryptography, which is why the vendor characterizes the outcome as 'Authentication Abuse'. The CPE entry cpe:2.3:a:johnson_controls:easyio_fs32:*:*:*:*:*:*:*:* confirms the affected product family without pinning a single release, consistent with the stated fixed version of 3.0b63. The CVSS 4.0 vector (AV:A/AC:H/AT:P/PR:H/UI:N/VC:L/VI:H/VA:H/SC:H/SI:H/SA:H) and the independent CVSS 3.1 assessment (AV:A/AC:H/PR:H/UI:N/S:C/C:L/I:H/A:H) agree that confidentiality loss is limited while integrity and availability impact are high and cross a security scope boundary - expected for a BAS/field controller whose authentication can be subverted and which then influences downstream building systems. Vendor-supplied tags split between 'EasyIO FS32' and 'Information Disclosure', but the assessed vector indicates the practical risk is state manipulation and denial-of-service rather than pure data exposure.

Know when Easyio Fs32 gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (jci) PRIMARY 5.6 MEDIUM
CVSS:4.0/AV:A/AC:H/AT:P/PR:H/UI:N/VC:L/VI:H/VA:H/SC:H/SI:H/SA:H/E:P
vuln.today AI 7.5 HIGH

Adjacent vector and high privileges/complexity match the authentication-abuse precondition (AV:A/AC:H/PR:H); scope is Changed as subsequent systems are impacted, with low confidentiality but high integrity/availability impact.

3.1 AV:A/AC:H/PR:H/UI:N/S:C/C:L/I:H/A:H
4.0 AV:A/AC:H/AT:P/PR:H/UI:N/VC:L/VI:H/VA:H/SC:H/SI:H/SA:H

Primary rating from Vendor (jci).

CVSS VectorVendor: jci

Attack Vector
Adjacent
Attack Complexity
High
Attack Requirements
Present
Privileges Required
High
User Interaction
None
Vulnerable system: Confidentiality
Low
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
High
Subsequent system: Integrity
High
Subsequent system: Availability
High

Lifecycle Timeline

1
Patch available
Oct 01, 2026 - 22:18 EUVD

DescriptionCVE.org

: Insecure Default Initialization of Resource vulnerability in Johnson Controls EasyIO FS32 allows : Authentication Abuse.

This issue affects EasyIO FS32: before 3.0b63.

Threat Intelligence Overview

EPSS Score
0.1%
Top 97% exploitable
Prevalence
Low
niche building-automation HVAC controller, industry-specific deployment footprint
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity MEDIUM
CISA KEV No
Public POC No
EPSS 0.1%
Patch available Yes
Active threat No
Deciding rule
MEDIUM severity (CVSS 4.0-6.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation
None
System Exposure· derived
Controlled
Automatable
No
Human Impact· derived
Medium
Technical Impact
Partial

Priority Score

28
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +28
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy