Skip to main content

Tenda CVE-2026-5045

| EUVDEUVD-2026-17031 HIGH
Stack-based Buffer Overflow (CWE-121)
2026-03-29 VulDB
7.4
CVSS 4.0 · NVD
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Authenticate to Tenda FH1201 web interface
  2. Delivery
    Send crafted request to /goform/WrlclientSet
  3. Exploit
    Manipulate GO parameter with oversized input
  4. Execution
    Trigger stack-based buffer overflow
  5. Impact
    Execute arbitrary code on device

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Stack buffer bounds checking
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Requires authenticated access to Tenda FH1201 firmware version 1.2.0.14(408). Attacker must send crafted POST request to /goform/WrlclientSet endpoint with malicious GO parameter to trigger stack-based buffer overflow in WrlclientSet function.

Impact

Real-world risk is HIGH despite requiring authentication. The CVSS 8.8 score reflects network-based attack vector (AV:N), low complexity (AC:L), and complete system compromise potential (C:H/I:H/A:H). Critically, authentication requirement is low-privilege (PR:L), meaning default or weak router credentials often satisfy this barrier. Public exploit code exists on GitHub (E:P confirmed), significantly lowering the skill threshold for exploitation. While not listed in CISA KEV (no confirmed active exploitation campaigns), the combination of publicly available POC, widespread deployment of consumer routers, and common credential weaknesses elevates practical risk. SSVC factors indicate moderate-to-high priority: exploitation is demonstrated (POC public), technical impact is total system compromise, and while not fully automatable (requires auth), credential stuffing or default password attacks enable broad targeting. The lack of vendor patch (RL:X) means vulnerable devices remain exposed indefinitely unless replaced or isolated. This is a legitimate high-priority issue, not inflated CVSS.

Exploit ScenarioDerived

An attacker conducts reconnaissance identifying Tenda FH1201 routers exposed via default credentials or harvested through credential stuffing attacks against the web management interface. After authenticating with low-privilege credentials (often 'admin:admin' on consumer routers), the attacker crafts a malicious HTTP request to /goform/WrlclientSet with an oversized 'GO' parameter payload containing shellcode. The stack-based overflow overwrites the return address, redirecting execution to attacker-controlled code running with router system privileges. The attacker establishes persistent backdoor access, pivots to internal network resources, intercepts traffic, or enlists the router in a botnet. Low attack complexity (AC:L) and network-based vector (AV:N) enable mass exploitation campaigns against internet-facing devices.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.0% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 29, 2026

Stack-based buffer overflow in Tenda FH1201 router (v1.2.0.14) enables remote authenticated attackers to execute arbitrary code via the WrlclientSet function. Exploitation requires only low-privilege credentials (CVSS PR:L) and has low attack complexity (AC:L), with publicly available exploit code on GitHub. CVSS 8.8 reflects high impact across confidentiality, integrity, and availability. No vendor patch identified at time of analysis, creating urgent risk for deployed devices.

RemediationAI

No vendor-released patch identified at time of analysis based on available references. Primary mitigation requires restricting network access to the router's administrative interface: disable remote management features, implement strict firewall rules allowing admin access only from trusted internal IP addresses, and change default credentials to complex unique passwords. Consider replacing affected Tenda FH1201 devices with alternative router models from vendors with active security support programs if firmware updates are not forthcoming. Monitor the vendor security page at https://www.tenda.com.cn/ and VulDB tracking page https://vuldb.com/vuln/353968 for potential future patches. Network segmentation isolating IoT/router management interfaces from general user networks reduces lateral movement risk post-compromise. Given the public exploit at https://github.com/Litengzheng/vul_db/blob/main/FH1201/vul_43/README.md, organizations should treat all exposed FH1201 devices as high-priority remediation targets.

Affected VersionsENISA

FH1201 1.2.0.14(408)

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability affects the WrlclientSet function within the /goform/WrlclientSet endpoint of the Tenda FH1201 wireless router's web-based parameter handler. The flaw is a CWE-121 stack-based buffer overflow triggered by insufficient input validation on the 'GO' parameter. When processing this parameter, the application copies user-controlled data to a fixed-size stack buffer without proper boundary checks, allowing an attacker to overwrite adjacent memory including return addresses. The affected product is identified as cpe:2.3:a:tenda:fh1201:*:*:*:*:*:*:*:* running firmware version 1.2.0.14(408). Stack-based buffer overflows in embedded device web interfaces are particularly dangerous because they typically run with elevated privileges and may bypass modern exploit mitigations common in desktop operating systems.

Know when Tenda gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 7.4 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

2
PoC Detected
Mar 30, 2026 - 15:46 vuln.today
Public exploit code
CVE Published
Mar 29, 2026 - 13:15 nvd
HIGH 7.4

DescriptionCVE.org

A vulnerability was detected in Tenda FH1201 1.2.0.14(408). This impacts the function WrlclientSet of the file /goform/WrlclientSet of the component Parameter Handler. Performing a manipulation of the argument GO results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.

Executive ViewAI

Why It Matters

CVE-2026-5045 is a critical remote code execution vulnerability in Tenda FH1201 routers (v1.2.0.14) that allows authenticated users with low-privilege network access to completely compromise affected devices. With publicly available exploit code and no vendor patch available, organizations deploying these routers face immediate risk of unauthorized system takeover, data exfiltration, and network pivoting-particularly concerning if these devices serve as network perimeter or remote access entry points.

Business Impact: Severe
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations: (1) Disable remote management features and restrict administrative access to local/trusted networks only; (2) Implement strong authentication controls to limit low-privilege user accounts; (3) Deploy network-level access controls (ACLs, VPN enforcement) to reduce exposure of management interfaces; (4) Enable router logging and establish alerts for unauthorized authentication attempts; (5) Isolate affected routers on a separate management network; (6) Monitor vendor security advisories and firmware release channels for patch availability.

Threat Intelligence Overview

EPSS Score
0.0%
Top 86% exploitable
Exploit
POC
Public exploit code exists
Data Quality
6 sources
Confidence: High
EUVD NVD CVE.org EPSS Vulnrichment GitHub VulDB

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC Yes
EPSS 0.0%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Out-of-Cycle
Exploitation
Poc
System Exposure· derived
Open
Automatable
No
Human Impact
Very High
Technical Impact
Total

Priority Score

57
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +37
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

A stack-based buffer overflow occurs when a program writes more data to a buffer located on the stack than it was allocated to hold.

Related Vulnerabilities in Tenda Router Buffer Overflow Flaws

View all 3

More in Tenda

View all
CVE-2022-30023 HIGH POC
8.8 Jun 16

Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function. Rated high sev

CVE-2015-5995 CRITICAL POC
9.8 Dec 31

Mediabridge Medialink MWN-WAPR300N devices with firmware 5.07.50 and Tenda N3 Wireless N150 devices allow remote attacke

CVE-2014-5246 CRITICAL POC
10.0 Aug 22

The Shenzhen Tenda Technology Tenda A5s router with firmware 3.02.05_CN allows remote attackers to bypass authentication

CVE-2025-45042 CRITICAL POC
9.8 May 05

Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function. Rated critic

CVE-2025-29384 CRITICAL POC
9.8 Mar 14

In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability

CVE-2025-44877 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via

CVE-2025-44872 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via

CVE-2022-32386 CRITICAL POC
9.8 Jul 06

Tenda AC23 v16.03.07.44 was discovered to contain a buffer overflow via fromAdvSetMacMtuWan. Rated critical severity (CV

CVE-2025-25632 CRITICAL POC
9.8 Mar 05

Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet. Rated critical se

CVE-2023-51972 CRITICAL POC
9.8 Jan 10

Tenda AX1803 v1.0.0.1 was discovered to contain a command injection vulnerability via the function fromAdvSetLanIp. Rate

CVE-2023-51812 CRITICAL POC
9.8 Jan 04

Tenda AX3 v16.03.12.11 was discovered to contain a remote code execution (RCE) vulnerability via the list parameter at /

CVE-2023-23080 CRITICAL POC
9.8 Feb 27

Certain Tenda products are vulnerable to command injection. Rated critical severity (CVSS 9.8), this vulnerability is re