Skip to main content

Tenda CVE-2026-5045

| EUVDEUVD-2026-17031 HIGH
Stack-based Buffer Overflow (CWE-121)
2026-03-29 VulDB
7.4
CVSS 4.0 · NVD
Share

Severity by source

NVD PRIMARY
7.4 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

4
PoC Detected
Mar 30, 2026 - 15:46 vuln.today
Public exploit code
EUVD ID Assigned
Mar 29, 2026 - 13:45 euvd
EUVD-2026-17031
Analysis Generated
Mar 29, 2026 - 13:45 vuln.today
CVE Published
Mar 29, 2026 - 13:15 nvd
HIGH 7.4

DescriptionCVE.org

A vulnerability was detected in Tenda FH1201 1.2.0.14(408). This impacts the function WrlclientSet of the file /goform/WrlclientSet of the component Parameter Handler. Performing a manipulation of the argument GO results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.

AnalysisAI

Stack-based buffer overflow in Tenda FH1201 router (v1.2.0.14) enables remote authenticated attackers to execute arbitrary code via the WrlclientSet function. Exploitation requires only low-privilege credentials (CVSS PR:L) and has low attack complexity (AC:L), with publicly available exploit code on GitHub. CVSS 8.8 reflects high impact across confidentiality, integrity, and availability. No vendor patch identified at time of analysis, creating urgent risk for deployed devices.

Technical ContextAI

This vulnerability affects the WrlclientSet function within the /goform/WrlclientSet endpoint of the Tenda FH1201 wireless router's web-based parameter handler. The flaw is a CWE-121 stack-based buffer overflow triggered by insufficient input validation on the 'GO' parameter. When processing this parameter, the application copies user-controlled data to a fixed-size stack buffer without proper boundary checks, allowing an attacker to overwrite adjacent memory including return addresses. The affected product is identified as cpe:2.3:a:tenda:fh1201:*:*:*:*:*:*:*:* running firmware version 1.2.0.14(408). Stack-based buffer overflows in embedded device web interfaces are particularly dangerous because they typically run with elevated privileges and may bypass modern exploit mitigations common in desktop operating systems.

RemediationAI

No vendor-released patch identified at time of analysis based on available references. Primary mitigation requires restricting network access to the router's administrative interface: disable remote management features, implement strict firewall rules allowing admin access only from trusted internal IP addresses, and change default credentials to complex unique passwords. Consider replacing affected Tenda FH1201 devices with alternative router models from vendors with active security support programs if firmware updates are not forthcoming. Monitor the vendor security page at https://www.tenda.com.cn/ and VulDB tracking page https://vuldb.com/vuln/353968 for potential future patches. Network segmentation isolating IoT/router management interfaces from general user networks reduces lateral movement risk post-compromise. Given the public exploit at https://github.com/Litengzheng/vul_db/blob/main/FH1201/vul_43/README.md, organizations should treat all exposed FH1201 devices as high-priority remediation targets.

More in Tenda

View all
CVE-2022-30023 HIGH POC
8.8 Jun 16

Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function. Rated high sev

CVE-2015-5995 CRITICAL POC
9.8 Dec 31

Mediabridge Medialink MWN-WAPR300N devices with firmware 5.07.50 and Tenda N3 Wireless N150 devices allow remote attacke

CVE-2014-5246 CRITICAL POC
10.0 Aug 22

The Shenzhen Tenda Technology Tenda A5s router with firmware 3.02.05_CN allows remote attackers to bypass authentication

CVE-2025-45042 CRITICAL POC
9.8 May 05

Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function. Rated critic

CVE-2025-29384 CRITICAL POC
9.8 Mar 14

In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability

CVE-2025-44877 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via

CVE-2025-44872 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via

CVE-2022-32386 CRITICAL POC
9.8 Jul 06

Tenda AC23 v16.03.07.44 was discovered to contain a buffer overflow via fromAdvSetMacMtuWan. Rated critical severity (CV

CVE-2025-25632 CRITICAL POC
9.8 Mar 05

Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet. Rated critical se

CVE-2023-51972 CRITICAL POC
9.8 Jan 10

Tenda AX1803 v1.0.0.1 was discovered to contain a command injection vulnerability via the function fromAdvSetLanIp. Rate

CVE-2023-51812 CRITICAL POC
9.8 Jan 04

Tenda AX3 v16.03.12.11 was discovered to contain a remote code execution (RCE) vulnerability via the list parameter at /

CVE-2025-45429 CRITICAL POC
9.8 Apr 23

In the Tenda ac9 v1.0 router with firmware V15.03.05.14_multi, there is a stack overflow vulnerability in /goform/WifiWp

Share

CVE-2026-5045 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy