Skip to main content

PowerProtect Data Domain CVE-2026-46468

| EUVDEUVD-2026-41542 MEDIUM
Improper Link Resolution Before File Access (CWE-59)
2026-07-03 security_alert@emc.com GHSA-fpc8-735f-w5qv
4.4
CVSS 3.1 · Vendor: emc
Share

Severity by source

Vendor (emc) PRIMARY
4.4 MEDIUM
AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
vuln.today AI
4.4 MEDIUM

Local access and high privileges required to plant symlinks; only confidentiality is impacted as no write or availability effect is described.

3.1 AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
4.0 AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N

Primary rating from Vendor (emc).

CVSS VectorVendor: emc

CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
Attack Vector
Local
Attack Complexity
Low
Privileges Required
High
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

Lifecycle Timeline

2
Patch available
Jul 03, 2026 - 14:01 EUVD
Analysis Generated
Jul 03, 2026 - 13:31 vuln.today

DescriptionCVE.org

Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access ('Link following') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.

AnalysisAI

Dell PowerProtect Data Domain exposes sensitive file content to high-privileged local attackers through a symlink-following flaw (CWE-59), where the application fails to validate link targets before file access. Affected versions span multiple release trains including the current 8.x mainline and LTS branches. No public exploit code has been identified at time of analysis, and this vulnerability is not listed in the CISA KEV catalog.

Technical ContextAI

CWE-59 (Improper Link Resolution Before File Access, 'Link Following') occurs when an application follows symbolic links without verifying that the resolved path is within an intended scope or that the calling process is authorized to access the destination. On Linux-based storage appliances like Data Domain, privileged processes that traverse filesystem paths without O_NOFOLLOW or equivalent protections can be redirected by symlinks planted by a local high-privilege user to read arbitrary files - including credentials, configuration, or encryption key material. The affected product is Dell's PowerProtect Data Domain deduplication backup appliance, covering versions 7.7.1.0-8.7 (mainline), LTS2026 8.6.1.0-8.6.1.10, LTS2025 8.3.1.0-8.3.1.30, and LTS2024 7.13.1.0-7.13.1.70, as stated in DSA-2026-278.

RemediationAI

Apply the vendor-released patches documented in Dell DSA-2026-278 (https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities); the advisory covers all affected LTS and mainline release trains. Exact fixed versions are not independently stated in the available input data beyond the advisory reference - consult the advisory directly to identify the correct target version for each release train. As a compensating control pending patching, restrict interactive and remote shell access (SSH) to the Data Domain management interface to only explicitly authorized administrators, reducing the pool of accounts that could meet the PR:H prerequisite. Additionally, audit local user accounts and role assignments on the appliance to ensure the principle of least privilege is enforced. Note that restricting shell access may impact break-glass procedures and should be coordinated with backup operations teams.

CVE-2025-29987 HIGH
8.8 Apr 03

Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) versions prior to 8.3.0.15 contain an Insufficie

CVE-2026-56086 HIGH
8.8 Jul 08

Improper authorization enforcement in Dell PowerProtect Data Domain (versions 7.7.1.0 through 8.6, plus LTS branches 8.6

CVE-2024-37140 HIGH
8.8 Jun 26

Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an OS command injection v

CVE-2024-29176 HIGH
8.8 Jun 26

Dell PowerProtect DD, version(s) 8.0, 7.13.1.0, 7.10.1.30, 7.7.5.40, contain(s) an Out-of-bounds Write vulnerability. Ra

CVE-2026-53482 HIGH
7.5 Jul 08

Denial of service in Dell PowerProtect Data Domain (DDOS versions 7.7.1.0 through 8.7, plus LTS2026 8.6.1.0-8.6.1.10, LT

CVE-2024-45759 HIGH
7.3 Nov 08

Dell PowerProtect Data Domain, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an escalation of

CVE-2024-48010 HIGH
7.2 Nov 08

Dell PowerProtect DD, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an access control vulnerab

CVE-2026-41122 HIGH
7.1 Jul 08

Stored cross-site scripting in Dell PowerProtect Data Domain (DD OS 7.7.1.0 through 8.7, plus the LTS2026 8.6.1.x, LTS20

CVE-2024-37138 MEDIUM
6.8 Jun 26

Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 on DDMC contain a relative path t

CVE-2026-54483 MEDIUM
6.7 Jul 03

OS command injection in Dell PowerProtect Data Domain enables a high-privileged local attacker to execute arbitrary oper

CVE-2026-26355 MEDIUM
6.5 Jul 03

OS command injection in Dell PowerProtect Data Domain across four version release trains allows a high-privileged remote

CVE-2025-46645 MEDIUM
6.5 Jan 09

Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) of Feature Release versions 7.7.1.0 through 8.4.

Share

CVE-2026-46468 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy