Severity by source
AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
Local access and high privileges required to plant symlinks; only confidentiality is impacted as no write or availability effect is described.
Primary rating from Vendor (emc).
CVSS VectorVendor: emc
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
Lifecycle Timeline
2DescriptionCVE.org
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access ('Link following') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.
AnalysisAI
Dell PowerProtect Data Domain exposes sensitive file content to high-privileged local attackers through a symlink-following flaw (CWE-59), where the application fails to validate link targets before file access. Affected versions span multiple release trains including the current 8.x mainline and LTS branches. …
Unlock full vulnerability intelligence
- Risk assessment & exploitation conditions
- Attack chain visualization
- Remediation with exact patch versions
- Threat intelligence from 22 sources
- Personal watchlist & email alerts
Free forever · No credit card required
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata
Vulnerability AssessmentAI
| Exploitation | Exploitation requires an attacker to already possess high-privileged (PR:H) local access to the Data Domain appliance - specifically, a shell-level account with sufficient OS permissions to create symbolic links in directories used by the vulnerable application. … Additional conditions and limiting factors are described in the full assessment. |
| Risk Assessment | The CVSS 3.1 base score of 4.4 (Medium) with vector AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N accurately reflects the constrained threat model: exploitation requires physical or remote shell access with high OS-level privileges, which significantly limits the attacker pool. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in. |
| Exploit Scenario | A local administrator or backup operator with an elevated shell session on the Data Domain appliance creates a symbolic link in a directory traversed by a privileged system process, redirecting file access to a sensitive target such as an internal configuration file containing credentials or encryption key references. When the vulnerable process accesses the symlink target without validation, its contents are exposed to the attacker. … |
| Remediation | Apply the vendor-released patches documented in Dell DSA-2026-278 (https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities); the advisory covers all affected LTS and mainline release trains. … Detailed patch versions, workarounds, and compensating controls in full report. |
Threat intelligence, references, and detailed analysis are available after sign-in.
More in Data Domain Operating System
View allDell PowerProtect Data Domain with Data Domain Operating System (DD OS) versions prior to 8.3.0.15 contain an Insufficie
Improper authorization enforcement in Dell PowerProtect Data Domain (versions 7.7.1.0 through 8.6, plus LTS branches 8.6
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an OS command injection v
Dell PowerProtect DD, version(s) 8.0, 7.13.1.0, 7.10.1.30, 7.7.5.40, contain(s) an Out-of-bounds Write vulnerability. Ra
Denial of service in Dell PowerProtect Data Domain (DDOS versions 7.7.1.0 through 8.7, plus LTS2026 8.6.1.0-8.6.1.10, LT
Dell PowerProtect Data Domain, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an escalation of
Dell PowerProtect DD, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an access control vulnerab
Stored cross-site scripting in Dell PowerProtect Data Domain (DD OS 7.7.1.0 through 8.7, plus the LTS2026 8.6.1.x, LTS20
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 on DDMC contain a relative path t
OS command injection in Dell PowerProtect Data Domain enables a high-privileged local attacker to execute arbitrary oper
OS command injection in Dell PowerProtect Data Domain across four version release trains allows a high-privileged remote
Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) of Feature Release versions 7.7.1.0 through 8.4.
Same weakness CWE-59 – Improper Link Resolution Before File Access
View allSame technique Information Disclosure
View allShare
External POC / Exploit Code
Leaving vuln.today
EUVD-2026-41542
GHSA-fpc8-735f-w5qv