Skip to main content

Tenda CVE-2026-4492

| EUVDEUVD-2026-13740 HIGH
Stack-based Buffer Overflow (CWE-121)
2026-03-20 VulDB
7.4
CVSS 4.0 · NVD
Share

Severity by source

NVD PRIMARY
7.4 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

6
Re-analysis Queued
Apr 22, 2026 - 21:37 vuln.today
cvss_changed
CVSS changed
Apr 22, 2026 - 21:37 NVD
8.8 (HIGH) 7.4 (HIGH)
PoC Detected
Mar 24, 2026 - 15:54 vuln.today
Public exploit code
EUVD ID Assigned
Mar 20, 2026 - 17:30 euvd
EUVD-2026-13740
Analysis Generated
Mar 20, 2026 - 17:30 vuln.today
CVE Published
Mar 20, 2026 - 17:02 nvd
HIGH 8.8

DescriptionCVE.org

A vulnerability was found in Tenda A18 Pro 02.03.02.28. The affected element is the function set_qosMib_list of the file /goform/formSetQosBand. Performing a manipulation of the argument list results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been made public and could be used.

AnalysisAI

Remote code execution in Tenda A18 Pro firmware 02.03.02.28 allows authenticated attackers to achieve full system compromise through stack-based buffer overflow in the QoS configuration function. Public exploit code exists for this vulnerability and no patch is currently available, leaving deployed devices at immediate risk.

Technical ContextAI

This vulnerability affects the Tenda A18 Pro wireless router (CPE: cpe:2.3:a:tenda:a18_pro), specifically firmware version 02.03.02.28 or earlier. The root cause is a CWE-121 stack-based buffer overflow occurring in the set_qosMib_list function within the Quality of Service (QoS) bandwidth configuration module at /goform/formSetQosBand. Stack-based buffer overflows occur when user-supplied data exceeds the allocated buffer size on the program stack without proper bounds checking, allowing attackers to overwrite return addresses and execute arbitrary code. The vulnerability is triggered through manipulation of the 'list' parameter, suggesting insufficient input validation on QoS configuration data submitted via the router's web management interface.

RemediationAI

Contact Tenda or check the vendor website at https://www.tenda.com.cn/ for firmware updates addressing this vulnerability, as the CVSS temporal metrics indicate no official remedy or workaround was available at initial disclosure (RL:X). Until patches become available, implement network-level compensating controls: restrict management interface access to trusted IP addresses only, disable remote administration features if not required, change default credentials to strong unique passwords, and place affected devices behind additional firewall layers to limit attack surface. Consider replacing the device with alternative hardware if Tenda does not release security updates in a timely manner, as consumer routers often receive limited long-term support. Monitor VulDB references at https://vuldb.com/?id.352018 and https://vuldb.com/?ctiid.352018 for updates on patch availability.

More in Tenda

View all
CVE-2022-30023 HIGH POC
8.8 Jun 16

Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function. Rated high sev

CVE-2015-5995 CRITICAL POC
9.8 Dec 31

Mediabridge Medialink MWN-WAPR300N devices with firmware 5.07.50 and Tenda N3 Wireless N150 devices allow remote attacke

CVE-2014-5246 CRITICAL POC
10.0 Aug 22

The Shenzhen Tenda Technology Tenda A5s router with firmware 3.02.05_CN allows remote attackers to bypass authentication

CVE-2025-45042 CRITICAL POC
9.8 May 05

Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function. Rated critic

CVE-2025-29384 CRITICAL POC
9.8 Mar 14

In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability

CVE-2025-44877 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via

CVE-2025-44872 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via

CVE-2022-32386 CRITICAL POC
9.8 Jul 06

Tenda AC23 v16.03.07.44 was discovered to contain a buffer overflow via fromAdvSetMacMtuWan. Rated critical severity (CV

CVE-2025-25632 CRITICAL POC
9.8 Mar 05

Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet. Rated critical se

CVE-2023-51972 CRITICAL POC
9.8 Jan 10

Tenda AX1803 v1.0.0.1 was discovered to contain a command injection vulnerability via the function fromAdvSetLanIp. Rate

CVE-2023-51812 CRITICAL POC
9.8 Jan 04

Tenda AX3 v16.03.12.11 was discovered to contain a remote code execution (RCE) vulnerability via the list parameter at /

CVE-2025-45429 CRITICAL POC
9.8 Apr 23

In the Tenda ac9 v1.0 router with firmware V15.03.05.14_multi, there is a stack overflow vulnerability in /goform/WifiWp

Share

CVE-2026-4492 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy