Phoenix Contact CHARX CVE-2026-44108

| EUVDEUVD-2026-51043 CRITICAL
Incorrect Behavior Order (CWE-696)
2026-07-30 info@cert.vde.com GHSA-hj6x-rh93-r6v7
9.3
CVSS 4.0 · Vendor: cert
Share

Severity by source

Vendor (cert) PRIMARY
9.3 CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
vuln.today AI
8.1 HIGH

Network, unauthenticated, no UI, and full compromise justify C/I/A:H and PR:N/UI:N, but exploitation depends on catching the transient shutdown window, so AC:H rather than AC:L.

3.1 AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (cert).

CVSS VectorVendor: cert

CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
X

Lifecycle Timeline

3
Analysis Generated
Jul 30, 2026 - 08:32 vuln.today
Patch available
Jul 30, 2026 - 08:03 EUVD
CVE Published
Jul 30, 2026 - 07:16 cve.org
CRITICAL 9.3

DescriptionCVE.org

Due to a flaw in the execution order of scripts during shutdown, the firewall is terminated prematurely during system shutdown. This creates a temporary window in which internal services may become externally accessible, potentially allowing an unauthenticated remote attacker to connect to these services, resulting in full system compromise.

AnalysisAI

Full system compromise of Phoenix Contact CHARX SEC EV charging controllers (SEC-3000/3050/3100/3150, versions 1.0.0 through 1.9.0) is possible because an incorrect script execution order tears down the firewall too early during system shutdown, briefly exposing internal-only services to the network. During this transient window a remote unauthenticated attacker can reach services that are normally firewalled off and gain complete control of the device. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
Gain network reachability to CHARX controller
Delivery
Await or induce device shutdown
Exploit
Firewall stops before internal services
Execution
Connect to exposed internal service
Persist
Exploit service for full compromise
Impact
Control charging controller

Vulnerability AssessmentAI

Exploitation Exploitation requires the device to be in its shutdown (or reboot) sequence - the vulnerable window exists only while the firewall has already been torn down but internal services are still running, per the description. … Additional conditions and limiting factors are described in the full assessment.
Risk Assessment The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H, score 9.3) rates this critical, implying trivially exploitable remote unauthenticated compromise. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario An attacker with network reachability to a CHARX SEC controller waits for or induces a device shutdown or reboot (e.g., during a maintenance cycle or power event) and, during the brief firewall-down window, connects to a normally-blocked internal service and leverages it to gain full control of the controller. Because the CVSS vector indicates network attack vector with no authentication or user interaction, the connection itself requires no credentials; the main obstacle is catching the shutdown timing window. …
Remediation Vendor-released patch: upgrade all affected CHARX SEC-3000/3050/3100/3150 controllers to firmware version 1.9.1 or later, which corrects the shutdown script ordering; follow the procedure in the vendor advisory at https://www.certvde.com/en/advisories/VDE-2026-008/. … Detailed patch versions, workarounds, and compensating controls in full report.

Recommended ActionAI

Within 24 hours, perform inventory of all deployed Phoenix Contact CHARX SEC controllers (models SEC-3000/3050/3100/3150) running firmware versions 1.0.0-1.9.0 and implement network-level access controls to restrict external connectivity to affected devices; simultaneously obtain the fixed firmware from Phoenix Contact referencing vendor advisory VDE-2026-008. …

Sign in for detailed remediation steps and compensating controls.

Threat intelligence, references, and detailed analysis are available after sign-in.

Share

CVE-2026-44108 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy