CVE-2025-8452
MEDIUMCVSS VectorNVD
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Lifecycle Timeline
2DescriptionNVD
By using the "uscan" protocol provided by the eSCL specification, an attacker can discover the serial number of multi-function printers that implement the Brother-provided firmware. This serial number can, in turn, can be leveraged by the flaw described by CVE-2024-51978 to calculate the default administrator password. This flaw is similar to CVE-2024-51977, with the only difference being the protocol by which an attacker can use to learn the remote device's serial number. The eSCL/uscan vector is typically only exposed on the local network. Any discovery service that implements the eSCL specification can be used to exploit this vulnerability, and one such implementation is the runZero Explorer. Changing the default administrator password will render this vulnerability virtually worthless, since the calculated default administrator password would no longer be the correct password.
AnalysisAI
By using the "uscan" protocol provided by the eSCL specification, an attacker can discover the serial number of multi-function printers that implement the Brother-provided firmware. Rated medium severity (CVSS 4.3), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified under CWE-538. By using the "uscan" protocol provided by the eSCL specification, an attacker can discover the serial number of multi-function printers that implement the Brother-provided firmware. This serial number can, in turn, can be leveraged by the flaw described by CVE-2024-51978 to calculate the default administrator password. This flaw is similar to CVE-2024-51977, with the only difference being the protocol by which an attacker can use to learn the remote device's serial number. The eSCL/uscan vector is typically only exposed on the local network. Any discovery service that implements the eSCL specification can be used to exploit this vulnerability, and one such implementation is the runZero Explorer. Changing the default administrator password will render this vulnerability virtually worthless, since the calculated default administrator password would no longer be the correct password.
Affected ProductsAI
See vendor advisory for affected versions.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Share
External POC / Exploit Code
Leaving vuln.today