Skip to main content

Siemens CVE-2017-9947

MEDIUM
Insertion of Sensitive Information into Externally-Accessible File (CWE-538)
2017-10-23 productcert@siemens.com
5.3
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V14 - Data Protection Sensitive file access control
Impact

CVSS score of 5.3 (MEDIUM). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. Public proof-of-concept exploit code is available. EPSS exploitation probability: 8.46%.

Exploit ScenarioDerived

This vulnerability can be exploited remotely over the network. Successful exploitation could compromise the medium-severity affected system.

This Month Plan within 30 days. Why: MEDIUM severity (CVSS 4.0-6.9).
No patch listed yet 8.5% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified under CWE-538. A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. A directory traversal vulnerability could allow a remote attacker with network access to the integrated web server (80/tcp and 443/tcp) to obtain information on the structure of the file system of the affected devices. Affected products include: Siemens Apogee Pxc Firmware, Siemens Apogee Pxc Modular Firmware, Siemens Talon Tc Compact Firmware, Siemens Talon Tc Modular Firmware.

Know when Siemens gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 5.3 MEDIUM
AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
None
Availability
None

DescriptionCVE.org

A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. A directory traversal vulnerability could allow a remote attacker with network access to the integrated web server (80/tcp and 443/tcp) to obtain information on the structure of the file system of the affected devices.

Threat Intelligence Overview

EPSS Score
8.5%
Top 8% exploitable
Exploit
POC
Public exploit code exists
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity MEDIUM
CISA KEV No
Public POC Yes
EPSS 8.5%
Patch available No
Active threat No
Deciding rule
MEDIUM severity (CVSS 4.0-6.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact· derived
Medium

Priority Score

54
Low Medium High Critical
KEV: 0
EPSS: +8
CVSS: +26
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Path traversal exploits occur when applications use user-controlled input to construct file system paths without proper validation.

Affected Products (CPE)CVE.org

cpe:2.3:o:siemens:apogee_pxc_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:talon_tc_compact_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:talon_tc_modular_firmware:*:*:*:*:*:*:*:*
CVE-2021-44228 CRITICAL POC
10.0 Dec 10

Apache Log4j2 contains a critical JNDI injection vulnerability known as 'Log4Shell' that allows unauthenticated remote c

CVE-2017-0144 HIGH POC
8.8 Mar 17

Remote code execution in Microsoft SMBv1 allows authenticated network attackers to execute arbitrary code on Windows sys

CVE-2010-2568 HIGH POC
7.8 Jul 22

Remote code execution in Windows Shell across XP through Windows 7 via malicious .LNK or .PIF shortcut files automatical

CVE-2017-0143 HIGH POC
8.8 Mar 17

The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows

CVE-2017-0146 HIGH POC
8.8 Mar 17

The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows

CVE-2017-0145 HIGH POC
8.8 Mar 17

The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows

CVE-2017-0148 HIGH POC
8.1 Mar 17

The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows

CVE-2021-40438 CRITICAL POC
9.0 Sep 16

A crafted request uri-path can cause mod_proxy to forward the request to an origin server choosen by the remote user.4.4

CVE-2017-0147 HIGH POC
7.5 Mar 17

The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows

CVE-2017-5689 CRITICAL POC
9.8 May 02

An unprivileged network attacker could gain system privileges to provisioned Intel manageability SKUs: Intel Active Mana

CVE-2014-0160 HIGH POC
7.5 Apr 07

The (1) TLS and (2) DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packe

CVE-2015-5374 HIGH POC
7.8 Jul 18

Siemens EN100 Ethernet module firmware across multiple protocol variants (PROFINET IO, Modbus TCP, DNP3 TCP, IEC 104) co

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy