Skip to main content

Fh1203 Firmware CVE-2025-69700

HIGH
Stack-based Buffer Overflow (CWE-121)
2026-02-23 cve@mitre.org
7.5
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
7.5 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

Lifecycle Timeline

3
Analysis Generated
Mar 12, 2026 - 21:55 vuln.today
PoC Detected
Feb 24, 2026 - 20:37 vuln.today
Public exploit code
CVE Published
Feb 23, 2026 - 14:16 nvd
HIGH 7.5

DescriptionCVE.org

Tenda FH1203 V2.0.1.6 contains a stack-based buffer overflow vulnerability in the modify_add_client_prio function, which is reachable via the formSetClientPrio CGI handler.

AnalysisAI

Tenda FH1203 V2.0.1.6 contains a stack-based buffer overflow vulnerability in the modify_add_client_prio function, which is reachable via the formSetClientPrio CGI handler. [CVSS 7.5 HIGH]

Technical ContextAI

Classified as CWE-121 (Stack-based Buffer Overflow). Affects the modify_add_client_prio component of Fh1203 Firmware. Tenda FH1203 V2.0.1.6 contains a stack-based buffer overflow vulnerability in the modify_add_client_prio function, which is reachable via the formSetClientPrio CGI handler.

RemediationAI

Monitor vendor advisories for a patch. Enable ASLR, DEP/NX, and stack canaries where possible. Restrict network access to the affected service where possible.

CVE-2024-30602 CRITICAL POC
9.8 Mar 28

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the schedStartTime parameter of the setSchedWifi function. R

CVE-2023-38940 CRITICAL POC
9.8 Aug 07

Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid

CVE-2023-38936 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28,

CVE-2023-38934 CRITICAL POC
9.8 Aug 07

Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the device

CVE-2023-38933 CRITICAL POC
9.8 Aug 07

Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0

CVE-2023-38931 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1

CVE-2023-37707 CRITICAL POC
9.8 Jul 10

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function.

CVE-2023-37706 CRITICAL POC
9.8 Jul 10

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the entrys parameter in the fromAddressNat function

CVE-2023-37705 CRITICAL POC
9.8 Jul 10

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromAddressNat function.

CVE-2023-37704 CRITICAL POC
9.8 Jul 10

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetClientState fu

CVE-2023-37703 CRITICAL POC
9.8 Jul 10

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan func

CVE-2023-37702 CRITICAL POC
9.8 Jul 10

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName fun

Share

CVE-2025-69700 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy