Delta DVP-12SE CVE-2025-62578

HIGH
Cleartext Transmission of Sensitive Information (CWE-319)
2025-12-26 759f5e80-c8e1-4224-bead-956d7b33c98b
7.2
CVSS 4.0 · Vendor: 759f5e80-c8e1-4224-bead-956d7b33c98b
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Gain foothold on adjacent OT network segment
  2. Delivery
    Intercept cleartext Modbus/TCP traffic (port 502)
  3. Exploit
    Capture sensitive data and craft Modbus requests
  4. Execution
    Inject unauthenticated commands to PLC
  5. Impact
    Manipulate or disrupt controller operation

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A04:2025 - Cryptographic Failures
ASVS 5.0
V12 - Secure Communication Transport encryption
Exploitation Conditions

Exploitation requires the attacker to hold a position on the adjacent/same-layer-2 network segment as the DVP-12SE PLC (CVSS AV:A - not internet-routable), from which the device's Modbus/TCP service (typically TCP port 502) transmits sensitive information in cleartext with no encryption and no authentication (PR:N). No user interaction or special product configuration is needed - Modbus/TCP's lack of transport security is the default protocol behavior. The primary limiting factor is the adjacency requirement: an attacker cannot exploit this directly over the internet and must first breach or gain access to the OT/local network, which in well-segmented ICS environments substantially narrows the realistic attack surface.

Impact

This is a moderate-priority industrial control systems (ICS) flaw rather than an urgent internet-wide emergency. The vendor-supplied CVSS 4.0 vector (AV:A/AC:L/AT:N/PR:N/UI:N) scores 7.2 (HIGH) and indicates an adjacent-network, low-complexity, unauthenticated attack requiring no user interaction - meaning any attacker who gains a foothold on the same local/OT network segment as the PLC can exploit it trivially. The AV:A (Adjacent) vector is the key risk-limiting signal: this is NOT remotely exploitable across the internet (not AV:N), so exploitation is gated on the attacker already having local network access to the OT environment. No EPSS score, CISA KEV listing, or public proof-of-concept was provided in the input, so there is no evidence of active exploitation or weaponization - exploitation status is 'no public exploit identified at time of analysis.' A notable internal tension exists in the vendor vector: the weakness is CWE-319 (Cleartext Transmission of Sensitive Information), which is fundamentally a confidentiality problem, yet the vendor rated VC:L (low confidentiality) but VI:H and VA:H (high integrity and availability impact). This implies the vendor views the unencrypted/unauthenticated Modbus/TCP channel as enabling not just passive sniffing but active injection/replay to manipulate or disrupt the PLC - verify this interpretation against the Delta advisory, as a pure cleartext-disclosure flaw would normally skew toward confidentiality rather than integrity/availability. Realistic risk is constrained by the ICS deployment context and adjacent-network requirement.

Exploit ScenarioDerived

An attacker who has already gained access to the operational technology (OT) network segment hosting the DVP-12SE PLC passively intercepts Modbus/TCP traffic (typically TCP port 502), which is transmitted in cleartext without encryption or authentication. The captured sensitive information (and the ability to inject crafted Modbus requests on the unauthenticated channel) allows the attacker to read process data and manipulate the controller's integrity and availability. No public exploit code was identified in the provided data, but Modbus/TCP interception requires only commodity network-sniffing tooling.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.3% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Oct 07, 2026

Cleartext transmission in Delta DVP-12SE PLC firmware causes sensitive Modbus/TCP traffic - process values, register contents, and control commands - to cross the network unencrypted and unauthenticated, letting an attacker on the same Layer-2 segment eavesdrop on, inject into, or modify communications with the device. The CVSS 4.0 base score of 7.2 is driven by the adjacency requirement (AV:A) and the absence of any authentication or user interaction (PR:N/UI:N), with impact scored as low confidentiality and high integrity/availability loss against the PLC itself; subsequent-system metrics are all None, so the flaw does not chain outward to other assets. No public exploit code and no confirmed active exploitation were identified at time of analysis, and because exploitation demands a foothold on the OT/adjacent network rather than internet reachability, this is a moderate-priority ICS issue rather than an urgent internet-wide emergency.

RemediationAI

No vendor-released patch identified at time of analysis; the provided data contains no fixed firmware version, so the primary reference for any available update or vendor-stated workaround is the Delta advisory Delta-PCSA-2025-00021 at https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00021_DVP-12SE%20ModbusTCP%20Cleartext%20Transmission%20of%20Sensitive%20Info.pdf, which should be consulted directly and monitored for a fixed release. Because the underlying flaw is Modbus/TCP's lack of native encryption and authentication, the effective mitigations are network-level: place the DVP-12SE on a dedicated OT VLAN isolated from business and guest networks, and apply host-level ACLs or industrial firewalls permitting TCP/502 only to the specific HMIs, SCADA servers, and engineering workstations that legitimately poll it - this blocks rogue clients and on-path attackers but will also break any unlisted controller that relies on the PLC, so the permitted-source list must be validated during a maintenance window. Where remote access or untrusted transit is unavoidable, tunnel Modbus/TCP through an IPsec or VPN gateway, accepting the added latency and the requirement that both endpoints terminate the tunnel. Supplement these controls with OT-aware deep packet inspection or an IDS/IPS that can alert on anomalous Modbus function codes, register-write bursts, or unexpected master addresses, and physically and logically restrict who can reach the PLC's Layer-2 segment, since an attacker who already holds that position defeats most perimeter controls.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

Modbus/TCP is a legacy industrial protocol originally derived from serial Modbus; it runs over TCP port 502 and, by design, provides no transport encryption, no session authentication, and no message integrity protection. The root cause class here is CWE-319 (Cleartext Transmission of Sensitive Information): the DVP-12SE firmware exposes operational data and command semantics in plaintext on the wire. The CPE cpe:2.3:o:deltaww:dvp-12se_firmware:*:*:*:*:*:*:*:* identifies Delta Electronics' DVP-12SE PLC firmware as the affected component, and the vendor's own advisory (Delta-PCSA-2025-00021) frames the issue specifically as Modbus/TCP cleartext transmission. The CVSS 4.0 vector AV:A/AC:L/AT:N/PR:N/UI:N confirms the attack is network-adjacent, low complexity, needs no privileges and no user interaction, and the all-None SC/SI/SA fields mean the impact is confined to the vulnerable device rather than cascading to downstream systems. Our independent CVSS 3.1 assessment (AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H) agrees on the adjacency and no-authentication prerequisites and rates integrity and availability loss on the PLC as high, since an on-path attacker can rewrite coil/register values or issue unauthorized commands while passively reading process data.

Know when Dvp 12Se Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (759f5e80-c8e1-4224-bead-956d7b33c98b) PRIMARY 7.2 HIGH
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N
vuln.today AI 8.3 HIGH

Adjacent-network cleartext Modbus with no auth gives AV:A/AC:L/PR:N/UI:N; low confidentiality but high integrity/availability from unauthenticated command injection on the PLC.

3.1 AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H
4.0 AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (759f5e80-c8e1-4224-bead-956d7b33c98b).

CVSS VectorVendor: 759f5e80-c8e1-4224-bead-956d7b33c98b

Attack Vector
Adjacent
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
Low
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

DescriptionCVE.org

DVP-12SE - Modbus/TCP Cleartext Transmission of Sensitive Information

Executive ViewAI

Why It Matters

Delta DVP-12SE programmable logic controllers, used for industrial process control, transmit Modbus/TCP traffic without encryption or authentication, exposing process values, register contents, and control commands to anyone with a presence on the same OT network segment. Because successful abuse requires an attacker to already hold a foothold on that adjacent network rather than reaching the devices from the internet, this is a contained but consequential OT exposure: a malicious insider, compromised engineering workstation, or vendor laptop on the plant floor could silently read or manipulate control logic. Leadership should care because manipulation of PLC communications can directly disrupt physical processes, halt production, or push equipment outside safe operating parameters, and no vendor patch is currently available to close the gap.

Business Impact: High
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations: isolate affected DVP-12SE PLCs on dedicated OT VLANs segmented by firewall from IT and general OT traffic; permit Modbus/TCP only between the PLCs and an allowlisted set of engineering hosts; implement Layer-2 hardening (port security, DHCP snooping, dynamic ARP inspection, unused port shutdown) to prevent rogue device attachment and spoofing; deploy OT network monitoring/IDS to detect anomalous Modbus reads and unauthorized writes; and restrict physical and logical access to the OT segment to vetted personnel.

Threat Intelligence Overview

EPSS Score
0.3%
Top 74% exploitable
Prevalence
Low
Delta DVP-12SE is a niche industrial PLC, industry-specific OT deployment
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.3%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Controlled
Automatable· derived
No
Human Impact
High

Priority Score

36
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +36
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.

Affected Products (CPE)CVE.org

cpe:2.3:o:deltaww:dvp-12se_firmware:*:*:*:*:*:*:*:*

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy