AutomationDirect Productivity Suite CVE-2025-61934
CRITICALAttack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessReach exposed ProductivityService on network
-
DeliveryConnect to unauthenticated PLC simulator
-
ExploitInvoke arbitrary file read/write/delete
-
ExecutionExfiltrate or tamper with host files
-
ImpactCompromise engineering workstation integrity
Vulnerability Assessment
| Weakness |
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Hardware binding mechanism
|
| Exploitation Conditions | Exploitation requires network reachability to the ProductivityService PLC simulator component of AutomationDirect Productivity Suite v4.4.1.19, which - per CWE-1327 - binds to an unrestricted IP address (e.g. 0.0.0.0/all interfaces) and listens without authentication, so any host that can route to the service port can invoke its file operations. No credentials, user interaction, or special configuration are needed (PR:N/UI:N/AC:L). The primary limiting factor is deployment topology: this is OT engineering-workstation/simulator software that is normally expected to run on segmented or isolated industrial networks, so realistic exposure depends on whether the affected host is reachable from untrusted or internet-facing segments rather than on any attacker-side prerequisite. |
| Impact | This is a genuine high-priority vulnerability, not a CVSS-inflated paper risk. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H, score 9.3 critical) describes unauthenticated, low-complexity, network-reachable exploitation with high confidentiality, integrity, and availability impact - fully consistent with the description's claim that a remote attacker can read, write, or delete arbitrary files via the ProductivityService PLC simulator. The signals are mostly aligned: the root cause (CWE-1327, binding to an unrestricted/0.0.0.0 IP address) directly explains the AV:N/PR:N rating because the service is reachable by any host that can route to it. The one tension is exposure context: EPSS is only 0.66% (51st percentile), which seems low for a 9.3 flaw, but this is expected for OT/ICS engineering software - it reflects lower internet-wide scanning volume and a smaller, often network-segmented install base rather than low technical severity. There is no CISA KEV listing and no public exploit identified at time of analysis, so there is no evidence of active exploitation yet. The practical mitigating factor is deployment: this is an engineering-workstation/simulator service that should sit on an isolated OT network, so real-world risk hinges heavily on whether the affected host is reachable from untrusted segments. |
| Exploit ScenarioDerived | An attacker with network reachability to an engineering workstation running Productivity Suite v4.4.1.19 connects directly to the ProductivityService PLC simulator, which is listening on an unrestricted interface with no authentication. Because the service exposes file operations, the attacker reads sensitive project/configuration files and then writes or deletes arbitrary files to tamper with the host or plant malicious content. No public exploit code is identified at time of analysis, but the low attack complexity (AC:L) and absence of authentication make exploitation straightforward for anyone who can reach the port. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 18, 2026
Unauthenticated file read, write, and deletion in AutomationDirect Productivity Suite 4.4.1.19 arises because the ProductivityService PLC simulator binds to an unrestricted IP address and does not require credentials or user interaction. Any network-reachable attacker can invoke file operations to read, write, or delete arbitrary files and folders under the service's permissions, although realistic exposure depends on whether the OT engineering workstation or simulator is reachable from untrusted segments. No public exploit was identified at time of analysis, and EPSS is low at 0.66% (51st percentile), but the potential impact is severe where the service is exposed.
RemediationAI
No vendor-released patch identified at time of analysis in the supplied data; consult AutomationDirect's security considerations and software downloads, plus CISA ICSA-25-296-01, to obtain the exact fixed Productivity Suite release and upgrade from v4.4.1.19. Until a fixed build is applied, restrict the ProductivityService listener to localhost or a specific trusted management interface if the product supports it, and block the service port at host and network firewalls so only authorized engineering hosts can reach the simulator; this may break legitimate remote PLC-simulation clients. Isolate the engineering workstation and simulator on a segmented OT VLAN with no route to IT or internet-facing networks, and stop or disable the simulator when it is not needed, accepting loss of simulation functionality. Run the service under a low-privileged account and tighten filesystem ACLs to limit the scope of arbitrary read, write, and delete operations; this can interfere with legitimate file access required by the simulator.
Affected ProductsAI
AutomationDirect Productivity Suite v4.4.1.19 is affected, specifically the ProductivityService PLC simulator component. No CPE string was supplied in the input. The CISA ICSA-25-296-01 advisory (https://www.cisa.gov/news-events/ics-advisories/icsa-25-296-01) and its CSAF JSON (https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-296-01.json) document the affected release, while AutomationDirect's security considerations (https://support.automationdirect.com/docs/securityconsiderations.pdf) and software downloads page (https://www.automationdirect.com/support/software-downloads) are the vendor references for remediation.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The issue is CWE-1327, Binding to an Unrestricted IP Address, in the ProductivityService PLC simulator component of AutomationDirect Productivity Suite v4.4.1.19. Rather than binding to localhost or a specific management interface, the service listens broadly and lacks authentication for its file operations, so any host that can route to the service port can trigger read, write, and delete actions against arbitrary files and folders under the service account. The independent CVSS 3.1 assessment (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H) is consistent with the provided CVSS 4.0 score of 9.3; the main limiting factor is deployment topology and OT network segmentation rather than any attacker-side prerequisite. No CPE mapping or public exploit code was supplied, and EPSS is 0.66% at the 51st percentile.
Know when the next one hits your stack
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L
Service binds to an unrestricted interface with no auth (AV:N/PR:N/AC:L/UI:N); arbitrary file read, write, and delete on the host yields C:H/I:H/A:H, scope unchanged.
Primary rating from Vendor (hq).
CVSS VectorVendor: hq
DescriptionCVE.org
A binding to an unrestricted IP address vulnerability was discovered in Productivity Suite software version v4.4.1.19. The vulnerability allows an unauthenticated remote attacker to interact with the ProductivityService PLC simulator and read, write, or delete arbitrary files and folders on the target machine
Executive ViewAI
AutomationDirect Productivity Suite 4.4.1.19, specifically the ProductivityService PLC simulator, carries a critical file-system risk: a network-reachable party can read, write, or delete arbitrary files under the service account, potentially disrupting engineering workstations and OT project integrity. Leadership should care because exposure depends on network reachability, but where the simulator is reachable from untrusted segments the blast radius includes loss or tampering of project files and service-level data. No public exploit was identified at time of analysis and EPSS is low, but the absence of a vendor-released patch requires immediate containment.
No vendor patch is available; restrict network reachability to the ProductivityService PLC simulator, disable the simulator where not required, segment the engineering workstation, enforce host firewall rules, run the service with least privilege, monitor file integrity on writable directories, and maintain offline backups of project files.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
NVD
CVE.org
EPSS
GitHub
Exploit-DB