Gallagher Command Centre
CVE-2025-47699
CRITICAL
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessAuthenticate as limited-permission operator
-
ExploitAccess Gallagher Morpho integration over network
-
ExecutionIssue out-of-scope config change to Morpho device
-
ImpactAlter/compromise local biometric access control
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V14 - Data Protection System info exposure prevention
|
| Exploitation Conditions | Requires (1) a valid authenticated Gallagher Command Centre Server operator account, even one with only limited site permissions, and (2) a deployment that has the Gallagher Morpho integration configured with local Morpho biometric devices; environments without the Morpho integration are not exposed. The vulnerability lets that operator exceed their authorized site scope to make critical changes to Morpho devices. Limiting factors: exploitation depends on prior authentication (insider or compromised operator credentials), so it is not anonymously reachable, and it is confined to installations running the Morpho integration on the affected versions (8.90 and prior, and 9.00/9.10/9.20/9.30 below the listed MR fix builds). |
| Impact | Despite a CVSS base score of 9.9 (Critical), the real-world risk profile is more nuanced. The vector CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H shows the score is driven largely by the scope change (S:C) - the flaw lets a Command Centre operator affect downstream Morpho biometric devices - combined with full C/I/A impact. Crucially, PR:L means exploitation is NOT unauthenticated: it requires a valid operator account that holds only limited site permissions, so the threat model is a malicious insider or a compromised/low-trust operator account rather than an anonymous internet attacker. Corroborating signals point to low immediate urgency: EPSS is only 0.34% (25th percentile), there is no CISA KEV listing, and no public proof-of-concept was identified. The signals are therefore consistent rather than conflicting - a high structural severity but low observed exploitation likelihood. One descriptive tension to verify with the vendor: CWE-497 and the 'Information Disclosure' tag frame this as sensitive-information exposure, yet the description's stated impact is that the operator can 'make critical changes to local Morpho devices,' which is an integrity/privilege-escalation outcome; the CVSS I:H reflects the latter. This is a genuine priority for organizations running the Gallagher Morpho integration (patch per the vendor advisory), but it is not an internet-wide, mass-exploitable emergency. |
| Exploit ScenarioDerived | A low-privilege Gallagher Command Centre operator - or an attacker who has phished/compromised such an operator's credentials - logs into the Command Centre Server over the network and abuses the Morpho integration to push critical configuration changes to local Morpho biometric readers beyond their authorized site scope, potentially weakening or reconfiguring physical access control. No special user interaction or elevated privileges are needed once the operator session exists; no public exploit code was identified at time of analysis. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 08, 2026
Authenticated Gallagher Command Centre Server operators holding only limited site permissions can abuse the Morpho integration to make critical configuration changes to local Morpho biometric devices, effectively exceeding their authorized site scope. The flaw is rated CVSS 9.9 (AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H) because the scope change lets a low-privileged account act beyond its intended security boundary, but exploitation requires a valid operator account and a deployment that actually has the Morpho integration configured - Command Centre installations without Morpho hardware are not exposed. Only 0.34% EPSS and no CISA KEV entry indicate low observed exploitation activity, and no public exploit code has been identified at time of analysis; the main risk is insider or compromised-credential abuse in Morpho-enabled environments.
RemediationAI
Apply the vendor maintenance releases that resolve CVE-2025-47699: upgrade 9.30 to vEL9.30.2482 (MR2), 9.20 to vEL9.20.2819 (MR4), 9.10 to vEL9.10.3672 (MR7), and 9.00 to vEL9.00.3831 (MR8); there is no fix build listed for 8.90 and earlier, so those installations must migrate to a supported, patched 9.x release, which carries the operational cost of a platform upgrade and validation of access-control configuration. Where immediate patching is not possible, compensate by auditing and de-provisioning Command Centre operator accounts that hold limited site permissions but do not require Morpho administration, by restricting which accounts are authorized to manage Morpho devices, and by monitoring Command Centre and Morpho device logs for configuration changes originating from accounts outside their assigned site scope; these controls reduce but do not eliminate the flaw because the vulnerable code path remains reachable after successful authentication, and revoking permissions may disrupt legitimate site operators. Patch reference: https://security.gallagher.com/en-NZ/Security-Advisories/CVE-2025-47699.
Affected ProductsAI
Affected software is Gallagher Command Centre Server running the Morpho integration on: 9.30 prior to vEL9.30.2482 (MR2), 9.20 prior to vEL9.20.2819 (MR4), 9.10 prior to vEL9.10.3672 (MR7), 9.00 prior to vEL9.00.3831 (MR8), and all versions of 8.90 and earlier. The vendor advisory is published at https://security.gallagher.com/en-NZ/Security-Advisories/CVE-2025-47699 and was reported by disclosures@gallagher.com; the associated CPE data identifies Command Centre Server as the vulnerable component, with exposure contingent on the Morpho integration being configured with local Morpho devices. Environments without the Morpho integration, and those already running the listed maintenance-release builds, are unaffected.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The issue is classified as CWE-497 (Exposure of Sensitive System Information to an Unauthorized Control Sphere) affecting the Gallagher Morpho integration shipped with Command Centre Server, a physical security and access-control management platform. The Morpho component is the biometric identity-enrollment and matching subsystem that Command Centre uses to administer local Morpho devices; the integration path fails to enforce the caller's site-permission boundary when relaying administrative operations to those devices. Root cause is therefore an authorization/scope-enforcement defect that surfaces as information-and-control exposure rather than a memory-safety or injection flaw. The CVSS scope-changed (S:C) vector with Confidentiality, Integrity and Availability all rated High reflects that the successful operator can influence a component outside the originally authorized control sphere - the Morpho devices themselves - while the PR:L metric confirms the attacker must first hold an authenticated Command Centre account.
Know when Gallagher gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Network-reachable server with low-complexity abuse; PR:L for the required limited-permission operator, S:C because a low-privileged operator impacts separately-managed Morpho devices with full C/I/A effect.
Primary rating from Vendor (gallagher).
CVSS VectorVendor: gallagher
DescriptionCVE.org
Exposure of Sensitive System Information to an Unauthorized Control Sphere (CWE-497) in the Gallagher Morpho integration could allow an authenticated operator with limited site permissions to make critical changes to local Morpho devices.
This issue affects Command Centre Server:
9.30 prior to vEL9.30.2482 (MR2), 9.20 prior to vEL9.20.2819 (MR4), 9.10 prior to vEL9.10.3672 (MR7), 9.00 prior to vEL9.00.3831 (MR8), all versions of 8.90 and prior.
Executive ViewAI
Gallagher Command Centre Server deployments with Morpho biometric integration are affected by a critical privilege escalation flaw (CVE-2025-47699) that allows authenticated operators with limited site permissions to make unauthorized configuration changes to biometric devices, potentially undermining physical access controls. Although no public exploit identified at time of analysis and observed exploitation is currently low, the vulnerability poses a significant insider threat or risk from compromised credentials, particularly in organizations relying on Morpho biometrics for secure facility access. Leadership should prioritize immediate access reviews and monitoring to prevent abuse of trusted operator accounts.
Restrict operator permissions to least privilege, enable detailed auditing of all Morpho configuration changes, segment network access between Command Centre and Morpho devices, enforce multi-factor authentication for all operator accounts, and consider temporary disablement of the Morpho integration if business operations permit. Monitor vendor advisory for patch release.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Controller 6000 is vulnerable to a buffer overflow via the Controller diagnostic web interface upload feature.80.230201a
It is possible to enumerate access card credentials via an unauthenticated network connection to the server in versions
An issue was discovered in Gallagher Command Centre 8.10 before 8.10.1092(MR2). Rated critical severity (CVSS 9.8), this
A format string issue in the Controller 6000's optional diagnostic web interface can be used to write/read from memory,
Improper Authorization vulnerability in Gallagher Command Centre Server allows command line macros to be modified by an
Type confusion in Gallagher Command Centre Server allows a remote attacker to crash the server or possibly cause remote
Installer log files across 15 Gallagher Command Centre service components write Service Account credentials in plaintext
Improper Authentication vulnerability in Gallagher Command Centre Server allows an unauthenticated remote attacker to cr
Client-Side enforcement of Server-Side security for the Command Centre server could be bypassed and lead to invalid conf
Improper validation of the cloud certificate chain in Mobile Connect allows man-in-the-middle attack to impersonate the
Improper Encoding or Escaping in Gallagher Command Centre Server allows a Command Centre Operator to alter the configura
Unquoted service path vulnerability in the Gallagher Controller Service allows an unprivileged user to execute arbitrary
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB