Skip to main content

FL Switch CVE-2025-41697

MEDIUM
Missing Protection Mechanism for Alternate Hardware Interface (CWE-1299)
2025-12-09 info@cert.vde.com
Fl Switch 2303 8sp1 Fl Nat 2208 Firmware Fl Nat 2304 2Gc 2Sfp Firmware Phoenixcontact Fl Switch 2708 Pn Firmware Fl Switch 2708 Firmware Fl Switch 2608 Pn Firmware Fl Switch 2608 Firmware Fl Switch 2516 Pn Firmware Fl Switch 2208C Firmware Fl Switch 2208 Pn Firmware Fl Switch 2208 Firmware Fl Switch 2207 Fx Sm Firmware Fl Switch 2207 Fx Firmware Fl Switch 2206C 2Fx Firmware Fl Switch 2206 2Sfx Pn Firmware Fl Switch 2206 2Sfx Firmware Fl Switch 2206 2Fx St Firmware Fl Switch 2206 2Fx Sm St Firmware Fl Switch 2206 2Fx Sm Firmware Fl Switch 2206 2Fx Firmware Fl Switch 2205 Firmware Fl Switch 2204 2Tc 2Sfx Firmware Fl Switch 2116 Firmware Fl Switch 2108 Firmware Fl Switch 2105 Firmware Fl Switch 2016 Firmware Fl Switch 2008F Firmware Fl Switch 2008 Firmware Fl Switch 2005 Firmware Fl Nat 2008 Firmware Fl Switch 2516 Firmware Fl Switch 2514 2Sfp Pn Firmware Fl Switch 2514 2Sfp Firmware Fl Switch 2512 2Gc 2Sfp Firmware Fl Switch 2508 Pn Firmware Fl Switch 2508 K1 Firmware Fl Switch 2508 Firmware Fl Switch 2506 2Sfp Pn Firmware Fl Switch 2506 2Sfp K1 Firmware Fl Switch 2506 2Sfp Firmware Fl Switch 2504 2Gc 2Sfp Firmware Fl Switch 2416 Pn Firmware Fl Switch 2416 Firmware Fl Switch 2414 2Sfx Pn Firmware Fl Switch 2414 2Sfx Firmware Fl Switch 2412 2Tc 2Sfx Firmware Fl Switch 2408 Pn Firmware Fl Switch 2408 Firmware Fl Switch 2406 2Sfx Pn Firmware Fl Switch 2406 2Sfx Firmware Fl Switch 2404 2Tc 2Sfx Firmware Fl Switch 2316 Pn Firmware Fl Switch 2316 K1 Firmware Fl Switch 2316 Firmware Fl Switch 2314 2Sfp Pn Firmware Fl Switch 2314 2Sfp Firmware Fl Switch 2312 2Gc 2Sfp Firmware Fl Switch 2308 Pn Firmware Fl Switch 2308 Firmware Fl Switch 2306 2Sfp Pn Firmware Fl Switch 2306 2Sfp Firmware Fl Switch 2304 2Gc 2Sfp Firmware Fl Switch 2216 Pn Firmware Fl Switch 2216 Firmware Fl Switch 2214 2Sfx Pn Firmware Fl Switch 2214 2Sfx Firmware Fl Switch 2214 2Fx Sm Firmware Fl Switch 2214 2Fx Firmware Fl Switch 2212 2Tc 2Sfx Firmware
6.8
CVSS 3.1 · Vendor: cert
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Gain physical access to device PCB
  2. Delivery
    Attach serial adapter to undocumented UART header
  3. Exploit
    Authenticate with credentials from CVE-2025-41692
  4. Execution
    Obtain root shell over console
  5. Impact
    Full compromise of switch OS

Vulnerability Assessment

Weakness
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Hardware write protection
Exploitation Conditions

Exploitation requires direct physical access to the device's printed circuit board to connect to an undocumented UART (serial console) port - the enclosure must be opened and a serial adapter attached to the header. Per the description, obtaining root also relies on device credentials sourced from CVE-2025-41692, making this a chained/companion attack rather than a standalone one. Limiting factors: AV:P means no network reachability is involved at all, so physical security of the cabinet/installation is the primary control; devices in locked, monitored OT enclosures are substantially harder to attack. This is most relevant for scenarios involving insider threat, supply-chain/shipping tampering, or physically exposed field-deployed switches.

Impact

Real-world priority is LOW despite the 6.8 (Medium) CVSS base score, and the score itself is driven by full C:H/I:H/A:H impact gated behind AV:P (physical access). The attacker must have physical possession of or hands-on access to the device's PCB to reach the undocumented UART port - this is not a remote or even adjacent-network issue. EPSS is 0.24% (13th percentile), there is no CISA KEV listing, and no public exploit code was identified, all consistent with a low likelihood of opportunistic exploitation. The signals are internally consistent: physical-only vector + low EPSS + no KEV = a hardware-hardening/supply-chain-tampering concern rather than an internet-facing emergency. Note the vulnerability chains with CVE-2025-41692 (referenced as the source of credentials), so its practical impact depends on that companion flaw; the description does not confirm whether root is obtainable via UART without those credentials. The 'Information Disclosure' tag understates impact - successful exploitation yields root (full confidentiality, integrity, and availability compromise), not mere disclosure.

Exploit ScenarioDerived

An attacker with physical access to a deployed FL Switch/FL NAT device (e.g. in an unsecured cabinet, during shipping, or via insider access) opens the enclosure, connects a serial adapter to the undocumented UART header on the PCB, and interacts with the exposed console. Using credentials obtained from CVE-2025-41692, they authenticate and obtain a root shell on the switch's operating system. No public exploit code is identified, and exploitation requires hands-on hardware access.

This Month Plan within 30 days. Why: MEDIUM severity (CVSS 4.0-6.9).
No patch listed yet 0.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Sep 30, 2026

Successful exploitation of an undocumented UART port on the printed circuit board of Phoenix Contact FL Switch and FL NAT industrial Ethernet switches allows an attacker with physical access to obtain root-level control, particularly when combined with credentials harvested via CVE-2025-41692. This chained attack requires opening the device enclosure and attaching a serial adapter; it is not network-reachable. Despite a CVSS base score of 6.8 (Medium), real-world priority is LOW due to the AV:P vector, and EPSS is 0.24% (13th percentile); no public exploit code or CISA KEV entry has been identified at time of analysis.

RemediationAI

No vendor-released patch is identified in the available intelligence; consult the CERT VDE advisory VDE-2025-071 for firmware updates and vendor guidance. Until a patch is applied, the primary mitigation is robust physical security: install devices in locked, monitored cabinets with tamper-evident seals and restrict physical access to authorized personnel only. Because root access also depends on credentials from CVE-2025-41692, address that vulnerability first by rotating any default or hardcoded credentials to strong unique values, if possible, or by updating firmware that fixes the credential exposure. For high-assurance environments, consider disabling or physically removing the UART header (e.g., desoldering or potting the connector) - but be aware this may void the warranty and is not feasible in all installations. Network-level controls (firewalls, segmentation) do not mitigate this physical attack vector. Trade-offs: physical controls are deterrent but not foolproof; tamper seals can be defeated, and monitoring may not detect brief connections.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The vulnerability is classified as CWE-1299 (Missing Protection Mechanism for Alternate Hardware Interface), meaning the device firmware lacks authentication or access controls on a debug UART header that is not documented for end users. This UART provides a direct serial console to the underlying operating system, bypassing normal network-based authentication. An attacker who can physically access the PCB can connect a UART adapter (e.g., via TX/RX/GND pins) and, using credentials obtained from CVE-2025-41692 (likely hardcoded or default credentials), escalate to root. The CVSS vector CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H confirms the physical attack vector, no privileges or user interaction required, and high impact to confidentiality, integrity, and availability. Affected CPEs cover numerous Phoenix Contact FL Switch and FL NAT models across all firmware versions.

Know when Fl Switch 2303 8sp1 gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (cert) PRIMARY 6.8 MEDIUM
AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
vuln.today AI 6.8 MEDIUM

Undocumented UART requires physical PCB access (AV:P) with low complexity and no prior auth on the port itself; a root shell yields full C/I/A compromise.

3.1 AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
4.0 AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (cert).

CVSS VectorVendor: cert

Attack Vector
Physical
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionCVE.org

An attacker can use an undocumented UART port on the PCB as a side-channel to get root access e.g. with the credentials obtained from CVE-2025-41692.

Threat Intelligence Overview

EPSS Score
0.2%
Top 87% exploitable
Prevalence
Low
industry-specific OT/ICS industrial ethernet switches, niche vendor footprint
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity MEDIUM
CISA KEV No
Public POC No
EPSS 0.2%
Patch available No
Active threat No
Deciding rule
MEDIUM severity (CVSS 4.0-6.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Defer
Exploitation· derived
None
System Exposure· derived
Small
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

34
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +34
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Affected Products (CPE)CVE.org

cpe:2.3:o:phoenixcontact:fl_switch_2708_pn_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2708_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2608_pn_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2608_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2516_pn_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2516_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2514-2sfp_pn_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2514-2sfp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2512-2gc-2sfp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2508_pn_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2508\/k1_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2508_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2506-2sfp_pn_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2506-2sfp\/k1_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2506-2sfp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2504-2gc-2sfp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2416_pn_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2416_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2414-2sfx_pn_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:phoenixcontact:fl_switch_2414-2sfx_firmware:*:*:*:*:*:*:*:*
+ 49 more
CVE-2025-41752 HIGH
7.1 Dec 09

Reflected cross-site scripting in the pxc_portSfp.php page of the web-based management (WBM) interface on Phoenix Contac

CVE-2025-41751 HIGH
7.1 Dec 09

Reflected cross-site scripting (XSS) in the pxc_portCntr.php endpoint of Phoenix Contact FL SWITCH and FL NAT industrial

CVE-2025-41750 HIGH
7.1 Dec 09

Reflected cross-site scripting (CWE-79) in the pxc_PortCfg.php script of Phoenix Contact's web-based management (WBM) in

CVE-2025-41748 HIGH
7.1 Dec 09

Cross-site scripting in the pxc_Dot1xCfg.php 802.1X configuration page of Phoenix Contact FL Switch and FL NAT industria

CVE-2025-41747 HIGH
7.1 Dec 09

Cross-site scripting in the Phoenix Contact FL SWITCH and FL NAT web-based management (WBM) interface - specifically the

CVE-2025-41746 HIGH
7.1 Dec 09

Cross-site scripting in the web-based management (WBM) interface of Phoenix Contact FL SWITCH industrial Ethernet switch

CVE-2025-41695 HIGH
7.1 Dec 09

Configuration tampering through cross-site scripting in dyn_conn.php affects the web-based management (WBM) interface of

CVE-2025-41749 HIGH
7.1 Dec 09

Reflected cross-site scripting in port_util.php within the web-based management (WBM) interface of Phoenix Contact FL SW

CVE-2025-41745 HIGH
7.1 Dec 09

Cross-site scripting in the pxc_portCntr2.php endpoint of the web-based management (WBM) interface of Phoenix Contact FL

CVE-2026-22317 HIGH
7.2 Mar 18

Arbitrary command execution with root privileges affects multiple Fl Switch and Fl Nat devices through improper handling

CVE-2026-22322 HIGH
7.1 Mar 18

A cross-site scripting vulnerability (CVSS 7.1) that allows an unauthenticated remote attacker. High severity vulnerabil

CVE-2026-22323 HIGH
7.1 Mar 18

A CSRF vulnerability in A CSRF vulnerability in the Link Aggregation configuration interface (CVSS 7.1) that allows an u

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy