SINEC Security Monitor
CVE-2025-40831
HIGH
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessAuthenticate with low-privileged account
-
DeliveryAccess report generation feature
-
ExploitSubmit malformed date parameter
-
ExecutionTrigger input-validation failure (CWE-20)
-
ImpactReport functionality denial of service
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V2 - Validation and Business Logic Input validation, allowlisting
|
| Exploitation Conditions | Exploitation requires an authenticated, low-privileged account on SINEC Security Monitor (versions below V4.10.0) and access to the report-generation functionality, where a malformed value in the date parameter triggers the unvalidated-input DoS. Limiting factors: valid credentials are mandatory (PR:L - not exploitable by anonymous/unauthenticated attackers), the impact is confined to the report feature rather than the whole application, and all versions at or above V4.10.0 are not affected. No user interaction or non-default configuration is required beyond having a usable account. |
| Impact | This is a moderate-severity, availability-only issue whose signals are mostly consistent and point to limited real-world urgency. The Siemens-assigned CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:L/UI:N) describes network-reachable, low-complexity exploitation but requires an authenticated, low-privileged account (PR:L), and the only impact is availability of the vulnerable system (VA:H) with no confidentiality or integrity effect (VC:N/VI:N). The description narrows that impact further to a denial of service of the report-generation functionality rather than the whole product, so the practical blast radius is a single feature, not the platform. EPSS is low at 0.39% (31st percentile), the CVE is NOT on CISA KEV, and no public exploit was provided - so there is no public exploit identified at time of analysis and no evidence of active exploitation. The one point worth flagging: Siemens rates availability as VA:H, but the prose scopes the DoS to the reporting feature only, which arguably supports a lower availability impact - defenders should treat the 7.1 as the upper bound for a feature-level outage, not a full product takedown. Net: a legitimate patch-management item for SINEC Security Monitor operators, but not a drop-everything priority given the authentication requirement, narrow impact, and absence of KEV/POC/high-EPSS signals. |
| Exploit ScenarioDerived | An attacker who already holds a low-privileged authenticated account on SINEC Security Monitor (below V4.10.0) navigates to the report-generation feature and submits a malformed value in the date parameter. Because the application fails to validate that input (CWE-20), the report functionality enters a denial-of-service condition, disrupting reporting for legitimate users. No public exploit code is known, and exploitation is bounded by the need for valid, if minimal, credentials. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 07, 2026
Improper validation of the date parameter in the report-generation feature of Siemens SINEC Security Monitor (all versions below V4.10.0) allows an authenticated, low-privileged user to submit a malformed date value and degrade or halt report generation, producing a denial-of-service condition confined to that functionality. Exploitation requires a valid account and access to the reporting feature - the CVSS vectors (PR:L) confirm it is not reachable by anonymous or unauthenticated attackers - and no public exploit code has been identified at time of analysis, with EPSS placing likelihood of exploitation at 0.39% (31st percentile). Siemens has released V4.10.0, which resolves the flaw; overall this is a moderate-severity, availability-only issue with limited real-world urgency.
RemediationAI
Upgrade SINEC Security Monitor to V4.10.0 or later - vendor-released patch: V4.10.0 - following the instructions in Siemens ProductCERT advisory SSA-882673 (https://cert-portal.siemens.com/productcert/html/ssa-882673.html). If upgrading cannot be done immediately, compensating controls should target the precondition (an authenticated low-privileged account invoking report generation): restrict report-generation privileges to a small set of trusted administrative roles so ordinary users cannot reach the vulnerable parameter (trade-off: reduces reporting availability for regular staff and requires role-model changes), and limit network exposure of the management/reporting interface to trusted administrative segments (trade-off: complicates remote administration but removes the attack path for non-admin users). Monitoring can supplement these: alert on repeated report-generation failures or anomalous date parameters in audit logs, and treat clustered failures as a possible DoS attempt. The DoS does not corrupt data and is recoverable by restarting or re-triggering the reporting service, so service-impact is temporary; no other workaround is published by the vendor at time of analysis, and no public exploit code has been identified.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The root cause is CWE-20 (Improper Input Validation): the application accepts a user-supplied date value during report generation and processes it without validating format, range, or type, so a crafted value triggers an unhandled error or resource-consumption condition that disrupts the reporting subsystem. The affected component is identified by CPE cpe:2.3:a:siemens:sinec_security_monitor:*:*:*:*:*:*:*:* - a Siemens security monitoring application - and the flaw is present in every release prior to V4.10.0. Impact is availability-only: the CVSS:3.1 assessment (AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L) shows no confidentiality or integrity loss and no scope change, meaning the failure is contained within the report-generation function rather than the whole product. Because the attack path requires network reachability to the interface plus a usable authenticated session, it is a post-authentication, low-privilege abuse case rather than a pre-auth remote compromise, and no non-default configuration or user interaction is needed beyond having an account that can invoke reporting.
Know when Sinec Security Monitor gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
Network-reachable low-complexity flaw needing a low-privileged account (PR:L); no confidentiality/integrity impact and DoS limited to the report feature, so A:L rather than A:H.
Primary rating from Vendor (siemens).
CVSS VectorVendor: siemens
DescriptionCVE.org
A vulnerability has been identified in SINEC Security Monitor (All versions < V4.10.0). The affected application lacks input validation of date parameter in report generation functionality. This could allow an authenticated, lowly privileged attacker to cause denial of service condition of the report functionality.
Executive ViewAI
Siemens SINEC Security Monitor instances running versions below V4.10.0 can have their report-generation capability degraded or halted by a user holding a valid low-privileged account. The impact is limited to availability of that reporting function rather than data confidentiality or integrity, and no public exploit or confirmed active exploitation has been identified; the CVSS vector (PR:L) indicates authenticated, low-privileged access is required. Leadership should view this as a contained operational risk to security reporting workflows owned by internal staff, not an external compromise threat, with remediation available through the vendor's V4.10.0 release.
Apply vendor patch.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Denial of Service attacks render applications or systems unavailable by overwhelming resources or triggering failure conditions.
Affected Products (CPE)CVE.org
More in Sinec Security Monitor
View allA vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). Rated critical severity (CVSS 9.4
A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). Rated critical severity (CVSS 9.3
Improper authorization in Siemens SINEC Security Monitor below V4.10.0 allows an authenticated, low-privileged local use
A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). Rated medium severity (CVSS 6.9),
A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). Rated medium severity (CVSS 5.3),
SINEC Security Monitor versions before 4.9.0 expose sensitive metadata including contributor information and email addre
NVD
CVE.org
EPSS
VulDB
GitHub PoC
Exploit-DB