Skip to main content

Simcenter Femap CVE-2025-40764

HIGH
Out-of-bounds Read (CWE-125)
2025-08-12 productcert@siemens.com
7.3
CVSS 4.0 · NVD
Share

Severity by source

NVD PRIMARY
7.3 HIGH
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Local
Attack Complexity
High
Privileges Required
None
User Interaction
P
Scope
X

Lifecycle Timeline

2
Analysis Generated
Mar 28, 2026 - 19:06 vuln.today
CVE Published
Aug 12, 2025 - 12:15 nvd
HIGH 7.3

DescriptionCVE.org

A vulnerability has been identified in Simcenter Femap V2406 (All versions < V2406.0003), Simcenter Femap V2412 (All versions < V2412.0002). The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.

AnalysisAI

A vulnerability has been identified in Simcenter Femap V2406 (All versions < V2406.0003), Simcenter Femap V2412 (All versions < V2412.0002). Rated high severity (CVSS 7.3), this vulnerability is no authentication required. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Out-of-bounds Read (CWE-125), which allows attackers to read data from memory outside the intended buffer boundaries. A vulnerability has been identified in Simcenter Femap V2406 (All versions < V2406.0003), Simcenter Femap V2412 (All versions < V2412.0002). The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process. Affected products include: Siemens Simcenter Femap.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate array indices and buffer lengths. Use memory-safe languages. Enable AddressSanitizer during testing.

CVE-2025-12659 HIGH
7.3 May 12

The affected applications contains a memory corruption vulnerability while parsing specially crafted IPT files. This cou

CVE-2025-40745 MEDIUM
6.3 Apr 14

Improper TLS certificate validation in Siemens Software Center, Simcenter 3D, Simcenter Femap, Simcenter STAR-CCM+, Soli

CVE-2026-23715 HIGH
7.8 Feb 10

Arbitrary code execution in Simcenter Femap and Nastran versions prior to V2512 results from an out-of-bounds write flaw

CVE-2026-23720 HIGH
7.8 Feb 10

Code execution in Simcenter Femap and Nastran versions prior to V2512 results from an out-of-bounds read flaw triggered

CVE-2026-23719 HIGH
7.8 Feb 10

Heap-based buffer overflow in Simcenter Femap and Nastran versions prior to V2512 allows local attackers to achieve arbi

CVE-2026-23718 HIGH
7.8 Feb 10

Out-of-bounds read in Simcenter Femap and Nastran versions prior to V2512 during NDB file parsing enables local code exe

CVE-2026-23717 HIGH
7.8 Feb 10

Simcenter Femap and Nastran versions prior to 2512 are vulnerable to out-of-bounds memory reads when processing maliciou

CVE-2026-23716 HIGH
7.8 Feb 10

Arbitrary code execution in Simcenter Femap and Nastran versions prior to 2512 results from an out-of-bounds read when p

CVE-2025-25175 HIGH
7.3 Mar 13

A vulnerability has been identified in Simcenter Femap V2401 (All versions < V2401.0003), Simcenter Femap V2406 (All ver

CVE-2025-40762 HIGH
7.3 Aug 12

A vulnerability has been identified in Simcenter Femap V2406 (All versions < V2406.0003), Simcenter Femap V2412 (All ver

Share

CVE-2025-40764 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy