CVE-2025-34157

CRITICAL
2025-08-27 [email protected]
9.4
CVSS 4.0
Share

CVSS Vector

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
P
Scope
X

Lifecycle Timeline

2
Analysis Generated
Mar 28, 2026 - 19:09 vuln.today
CVE Published
Aug 27, 2025 - 17:15 nvd
CRITICAL 9.4

Description

Coolify versions prior to v4.0.0-beta.420.6 are vulnerable to a stored cross-site scripting (XSS) attack in the project creation workflow. An authenticated user with low privileges can create a project with a maliciously crafted name containing embedded JavaScript. When an administrator attempts to delete the project or its associated resource, the payload executes in the admin’s browser context. This results in full compromise of the Coolify instance, including theft of API tokens, session cookies, and access to WebSocket-based terminal sessions on managed servers.

Analysis

Coolify versions prior to v4.0.0-beta.420.6 are vulnerable to a stored cross-site scripting (XSS) attack in the project creation workflow. Rated critical severity (CVSS 9.4), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Technical Context

This vulnerability is classified under CWE-20. Coolify versions prior to v4.0.0-beta.420.6 are vulnerable to a stored cross-site scripting (XSS) attack in the project creation workflow. An authenticated user with low privileges can create a project with a maliciously crafted name containing embedded JavaScript. When an administrator attempts to delete the project or its associated resource, the payload executes in the admin’s browser context. This results in full compromise of the Coolify instance, including theft of API tokens, session cookies, and access to WebSocket-based terminal sessions on managed servers. Affected products include: Coollabs Coolify.

Affected Products

Coollabs Coolify.

Remediation

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Priority Score

47
Low Medium High Critical
KEV: 0
EPSS: +0.1
CVSS: +47
POC: 0

Share

CVE-2025-34157 vulnerability details – vuln.today