Redis CVE-2025-1979

MEDIUM
Insertion of Sensitive Information into Log File (CWE-532)
2025-03-06 report@snyk.io
5.7
CVSS 4.0
Share

CVSS VectorNVD

CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:N/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Local
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

3
Patch released
Mar 31, 2026 - 21:13 nvd
Patch available
Analysis Generated
Mar 28, 2026 - 18:30 vuln.today
CVE Published
Mar 06, 2025 - 05:15 nvd
MEDIUM 5.7

Blast Radius

ecosystem impact
† from your stack dependencies † transitive graph · vuln.today resolves 4-path depth
  • 9 pypi packages depend on ray (8 direct, 1 indirect)

Ecosystem-wide dependent count for version 2.43.0.

DescriptionNVD

Versions of the package ray before 2.43.0 are vulnerable to Insertion of Sensitive Information into Log File where the redis password is being logged in the standard logging. If the redis password is passed as an argument, it will be logged and could potentially leak the password. This is only exploitable if: 1) Logging is enabled; 2) Redis is using password authentication; 3) Those logs are accessible to an attacker, who can reach that redis instance. Note: It is recommended that anyone who is running in this configuration should update to the latest version of Ray, then rotate their redis password.

AnalysisAI

Versions of the package ray before 2.43.0 are vulnerable to Insertion of Sensitive Information into Log File where the redis password is being logged in the standard logging. Rated medium severity (CVSS 5.7), this vulnerability is low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-532. Versions of the package ray before 2.43.0 are vulnerable to Insertion of Sensitive Information into Log File where the redis password is being logged in the standard logging. If the redis password is passed as an argument, it will be logged and could potentially leak the password. This is only exploitable if: 1) Logging is enabled; 2) Redis is using password authentication; 3) Those logs are accessible to an attacker, who can reach that redis instance. Note: It is recommended that anyone who is running in this configuration should update to the latest version of Ray, then rotate their redis password. Version information: before 2.43.0.

Affected ProductsAI

See vendor advisory for affected versions.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.