Skip to main content

Operation And Maintenance Management System CVE-2025-15499

HIGH
Command Injection (CWE-77)
2026-01-09 cna@vuldb.com
8.8
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Command injection prevention
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS 8.8 (HIGH). Attack vector: Network. Complexity: Low. Privileges required: Low. User interaction: None. Exploitable via remote/network. Public exploit/POC available.

Exploit ScenarioDerived

A remote attacker could exploit this flaw, os command injection.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.4% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 12, 2026

Operation And Maintenance Management System versions up to 3.0.8. is affected by command injection (CVSS 8.8).

RemediationAI

Monitor vendor advisories for a patch. Restrict network access to the affected service where possible.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability (CWE-77: Command Injection) affects Operation And Maintenance Management System. has been found in Sangfor Operation and Maintenance Management System up to 3.0.8. This vulnerability affects the function uploadCN of the file VersionController.java. The manipulation of the argument filename leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Know when Operation And Maintenance Management System gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

2
PoC Detected
Jan 22, 2026 - 21:46 vuln.today
Public exploit code
CVE Published
Jan 09, 2026 - 22:15 nvd
HIGH 8.8

DescriptionCVE.org

A vulnerability has been found in Sangfor Operation and Maintenance Management System up to 3.0.8. This vulnerability affects the function uploadCN of the file VersionController.java. The manipulation of the argument filename leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Executive ViewAI

Why It Matters

Organizations using Sangfor Operation and Maintenance Management System face significant risk from CVE-2025-15499, a command injection vulnerability rated CVSS 8.8. Successful exploitation could allow attackers to execute arbitrary code or commands on affected systems, potentially leading to full system compromise. Proof-of-concept code is publicly available, increasing the risk of exploitation. Organizations should apply vendor updates when available and consider compensating controls in the interim.

Business Impact: Severe
Compensating Controls

Apply vendor patch. If immediate patching is not feasible: (1) Deploy WAF rules to block injection patterns; (2) Restrict network access to affected components; (3) Enable enhanced logging for suspicious activity.

Threat Intelligence Overview

EPSS Score
0.4%
Top 40% exploitable
Exploit
POC
Public exploit code exists
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC Yes
EPSS 0.4%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Out-of-Cycle
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
No
Human Impact
Very High

Priority Score

64
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +44
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

Affected Products (CPE)CVE.org

cpe:2.3:a:sangfor:operation_and_maintenance_management_system:*:*:*:*:*:*:*:*

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy