CVE-2025-13053
HIGH
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessGain on-path network position between NAS and UPS
-
ExploitPresent forged/unvalidated TLS certificate
-
ExecutionIntercept UPS status/control session
-
ImpactObtain sensitive UPS server configuration data
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A06:2025 - Insecure Design
ASVS 5.0
V14 - Data Protection Encryption of sensitive data
|
| Exploitation Conditions | Exploitation requires that the NAS be explicitly configured to retrieve UPS status or control a UPS over the network (network UPS mode), so default installations without this UPS integration are not affected. Additionally, the attacker must hold a man-in-the-middle / on-path position on the network segment between the NAS client and the UPS server (reflected as AT:P in the CVSS 4.0 vector), because the flaw is non-enforced TLS certificate verification (CWE-311) rather than a directly reachable service. Limiting factors: the UPS feature must be enabled, the attacker must already intercept the traffic, and only ADM versions 4.1.0 through 4.3.3.RKD2 and 5.0.0 through 5.1.0.RN42 are in scope; impact is disclosure of UPS server configuration rather than full device compromise. |
| Impact | This is a moderate-severity information-disclosure weakness (CVSS 4.0 base 7.0) in ASUSTOR ADM, and the signals converge on LOW real-world urgency despite the 'High' label. The provided CVSS 4.0 vector is AV:N/AC:L/AT:P/PR:N/UI:N - note AT:P, meaning a specific attack requirement exists: the attacker must already be positioned to intercept traffic (on-path/MITM), which is a meaningful barrier even though the vector is 'network.' EPSS is only 0.10% (1st percentile), indicating essentially no observed or predicted mass exploitation. There is no CISA KEV listing and no public exploit code referenced, so exploitation status is 'no public exploit identified at time of analysis.' These signals agree: a MITM-dependent config-disclosure flaw in a consumer/SMB NAS OS is not a drive-by, wormable, or widely-weaponized issue. One point of tension worth flagging: the vendor's CVSS 4.0 vector rates subsequent-system impact high (SC:H/SI:H) while the description frames the issue purely as disclosure of UPS server configuration information - the subsequent integrity rating appears aggressive relative to the described impact; verify actual integrity/control consequences with the vendor advisory. Net: patch during normal maintenance cycles; this is not an emergency. |
| Exploit ScenarioDerived | On a LAN where an ASUSTOR NAS is configured to poll or control a network UPS, an attacker who can intercept traffic between the NAS and the UPS server (e.g., via ARP spoofing or a rogue gateway) presents a forged TLS certificate that the NAS fails to validate. The attacker then decrypts the session and captures sensitive UPS server configuration data. No public exploit code is referenced, and success requires the attacker to first achieve an on-path man-in-the-middle position. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 07, 2026
Interception of network traffic between an ASUSTOR ADM NAS and a UPS server can expose UPS server configuration data because ADM does not enforce TLS certificate verification when retrieving UPS status or issuing UPS control commands. Only NAS devices explicitly configured in network UPS mode are exposed, and the attacker must already hold an on-path (man-in-the-middle) position on the network segment; default installations without UPS integration are not affected. Affected builds are ADM 4.1.0 through 4.3.3.RKD2 and 5.0.0 through 5.1.0.RN42, and there is no public exploit identified at time of analysis, with EPSS at 0.10% (1st percentile) indicating low predicted real-world exploitation activity.
RemediationAI
Apply the firmware update prescribed by the ASUSTOR security advisory (https://www.asustor.com/security/security_advisory_detail?id=49); no explicit fixed build number is stated in the available data, so verify the corrected ADM release against that advisory before assuming a given image is patched. Until an updated build is confirmed and installed, the most effective compensating control is to disable remote/network UPS monitoring and control in ADM (fall back to a locally attached USB UPS or to no UPS integration), which removes the vulnerable client code path entirely - the trade-off is loss of graceful shutdown signaling on power events. If network UPS integration must remain, place the NAS and the UPS server on a dedicated, tightly segmented management VLAN with 802.1X or MAC/port-security enforcement to make on-path positioning difficult, and carry that UPS traffic inside an authenticated tunnel such as IPsec or an operator-controlled VPN - both measures add configuration and operational overhead and do not repair the missing certificate check itself. As a lower-friction hardening step, ensure the UPS server presents a certificate from a CA the NAS already trusts, since deployments relying on self-signed UPS certificates are the least likely to notice silent substitution. None of these workarounds should be treated as a substitute for the vendor firmware fix, and because EPSS is only 0.10% (1st percentile) with no KEV listing and no public exploit identified at time of analysis, prioritization can follow normal information-disclosure patching cadence rather than emergency response.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The issue sits in ASUSTOR ADM's UPS management component, which communicates with a remote UPS server (typically Network UPS Tools/NUT-style or vendor-specific UPS daemons) over the network when the administrator enables remote UPS status polling or UPS control. The advisory attributes the flaw to CWE-311 (Missing Encryption of Sensitive Data): the NAS-side client establishes the session but does not enforce validation of the server's TLS certificate, so a party positioned between client and server can present its own certificate and terminate the TLS session transparently. Behaviorally this overlaps with CWE-295 (Improper Certificate Validation) - the practical root cause is a missing chain-of-trust check rather than absent transport encryption. The CVSS 4.0 vector reflects this precisely: AV:N/AC:L/PR:N/UI:N but AT:P (Attack Requirements: Present), meaning the attacker must already be on-path, with low confidentiality impact on the vulnerable system (VC:L) but high subsequent impact on the connected UPS system (SC:H/SI:H), consistent with disclosure of UPS server configuration that could enable follow-on access to the UPS infrastructure. The independent assessment concurs with a CVSS 3.1 view of AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N - reconnaissance-grade information disclosure, not device compromise. The CPE records supplied (cpe:2.3:o:asustor:data_master:* with wildcarded versions) confirm the affected platform family but do not themselves enumerate the vulnerable version ranges, so the version data in the vendor advisory is authoritative.
Know when Data Master gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:H/SI:H/SA:L
MITM interception is a precondition so AC:H; the described impact is disclosure of UPS configuration only, giving C:L with no integrity or availability effect.
Primary rating from Vendor (asustor).
CVSS VectorVendor: asustor
DescriptionCVE.org
When a user configures the NAS to retrieve UPS status or control the UPS, a non-enforced TLS certificate verification can allow an attacker able to intercept network traffic between the client and server can perform a man-in-the-middle (MITM) attack, which may obtain the sensitive information of the UPS server configuation.
This issue affects ADM: from 4.1.0 through 4.3.3.RKD2, from 5.0.0 through 5.1.0.RN42.
Executive ViewAI
ASUSTOR ADM network-attached storage appliances running ADM 4.1.0 through 4.3.3.RKD2 or 5.0.0 through 5.1.0.RN42 can expose UPS server configuration data to anyone already positioned to intercept traffic on the same network segment, because the device does not verify TLS certificates when retrieving UPS status or sending UPS control commands. The exposure is limited to NAS units explicitly configured in network UPS mode, but those devices typically sit on shared infrastructure segments alongside backup and monitoring systems, so leaked UPS credentials and configuration could enable broader disruption of power-management and shutdown automation. With EPSS at 0.10% (1st percentile) and no public exploit identified at time of analysis, near-term exploitation risk is low, but the absence of a vendor fix means the risk persists until network controls or configuration changes are in place.
No vendor-released patch identified at time of analysis. Interim mitigations: disable network UPS mode on affected ADM builds where integration is not required; isolate NAS-to-UPS traffic on a dedicated VLAN protected by 802.1X, DHCP snooping, and dynamic ARP inspection; tunnel or proxy UPS management traffic through a locally controlled encrypted channel; rotate UPS server credentials and review UPS access logs for anomalous control commands; monitor for ARP spoofing or other on-path activity on affected segments.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Affected Products (CPE)CVE.org
More in Data Master
View allOS command injection in snmp.cgi in ASUSTOR ADM version 3.1.1 allows attackers to execute system commands without authen
Information disclosure in the SNMP settings page in ASUSTOR ADM version 3.1.1 allows attackers to obtain the SNMP passwo
OS command injection in group.cgi in ASUSTOR ADM version 3.1.1 allows attackers to execute system commands as root by mo
OS Command Injection in upload.cgi in ASUSTOR ADM version 3.1.1 allows attackers to execute system commands by modifying
OS command injection in user.cgi in ASUSTOR ADM version 3.1.1 allows attackers to execute system commands as root via th
OS command injection in user.cgi in ASUSTOR ADM version 3.1.1 allows attackers to execute system commands as root via th
Denial-of-service in the login page of ASUSTOR ADM 3.1.1 allows attackers to prevent users from signing in by placing ma
Directory Traversal in downloadwallpaper.cgi in ASUSTOR ADM version 3.1.1 allows attackers to download arbitrary files b
Directory Traversal in upload.cgi in ASUSTOR ADM version 3.1.1 allows attackers to upload files to arbitrary locations b
Directory Traversal in File Explorer in ASUSTOR ADM version 3.1.1 allows attackers to view arbitrary files by modifying
ASUSTOR Data Master 3.1.5 and below allows authenticated remote non-administrative users to upload files to arbitrary lo
Missing verification of a password in ASUSTOR ADM version 3.1.1 allows attackers to change account passwords without ent
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB