Ac23 Firmware
CVE-2025-12596
HIGH
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Lifecycle Timeline
3DescriptionCVE.org
A security vulnerability has been detected in Tenda AC23 16.03.07.52. Affected is the function saveParentControlInfo of the file /goform/saveParentControlInfo. Such manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed publicly and may be used.
AnalysisAI
A security vulnerability has been detected in Tenda AC23 16.03.07.52. Rated high severity (CVSS 7.4), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.
Technical ContextAI
This vulnerability is classified as Buffer Overflow (CWE-119), which allows attackers to corrupt memory to execute arbitrary code or crash the application. A security vulnerability has been detected in Tenda AC23 16.03.07.52. Affected is the function saveParentControlInfo of the file /goform/saveParentControlInfo. Such manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed publicly and may be used. Affected products include: Tenda Ac23 Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use memory-safe languages or bounds-checking. Enable ASLR, DEP/NX, stack canaries. Use safe string functions.