Skip to main content

Tenda AC7 CVE-2025-11528

HIGH
Buffer Overflow (CWE-119)
2025-10-09 cna@vuldb.com
7.4
CVSS 4.0 · Vendor: vuldb
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Authenticate to router web interface
  2. Exploit
    Send crafted POST to /goform/saveAutoQos with oversized 'enable'
  3. Execution
    Overflow stack buffer in QoS handler
  4. Impact
    Execute code or crash device

Vulnerability Assessment

Weakness
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, buffer size validation
MITRE ATT&CK

2 techniques across 2 tactics: Execution, Privilege Escalation

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Exploitation requires reaching the router's HTTP management interface and sending a manipulated 'enable' parameter to the /goform/saveAutoQos (Auto QoS save) endpoint. Per the CVSS vector (PR:L), the attacker needs low-privilege authenticated access to that web interface - not anonymous access - so valid or default credentials are a prerequisite. The practical limiting factor is reachability: the management interface is typically exposed only on the LAN unless WAN/remote management is enabled, which narrows realistic exposure to local attackers or devices with remote administration turned on.

Impact

This is a moderate-priority vulnerability whose real-world risk is tempered by its access requirements. The supplied CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:L/UI:N) scores 7.4 and indicates a network-reachable, low-complexity attack that nevertheless requires low-level privileges (PR:L) - i.e. an authenticated session on the router's management interface, not fully anonymous access. Impact is severe where it applies (VC:H/VI:H/VA:H), consistent with a stack-based buffer overflow (CWE-119) that can lead to code execution or device crash. Publicly available exploit code exists (referenced PoC on GitHub), but there is no CISA KEV listing, and the EPSS score is low at 0.80% (55th percentile), indicating no evidence of widespread automated exploitation at this time. The signals are therefore consistent rather than conflicting: a real but not emergency-grade issue - a working PoC against a consumer router, gated by authentication and (typically) LAN reachability. Note the AV:N classification assumes the HTTP management interface is network-reachable; on most deployments it is LAN-only unless remote/WAN management is explicitly enabled, which should be verified per deployment. Treat this as a prioritized patch for exposed or remotely-managed devices, not a drop-everything critical.

Exploit ScenarioDerived

An attacker with low-privilege access to the Tenda AC7 web management interface (e.g. via default or weak credentials, or an already-compromised LAN foothold) sends a crafted HTTP request to /goform/saveAutoQos with an oversized or malformed 'enable' argument. This overflows a stack buffer in the request handler, enabling denial of service or arbitrary code execution on the router. A public proof-of-concept for this endpoint is available on GitHub, lowering the barrier to reproduction.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.8% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Oct 08, 2026

Stack-based buffer overflow in the Tenda AC7 router firmware (version 15.03.06.44) lets an attacker who can reach the web management interface crash or potentially execute code on the device by sending a crafted 'enable' parameter to the /goform/saveAutoQos endpoint. Per the assessed CVSS vector (PR:L), exploitation requires low-privilege authenticated access to that interface, meaning valid or default credentials are a prerequisite, and reachability is normally limited to the LAN unless WAN/remote management is enabled. Publicly available exploit code exists and EPSS places the vulnerability in the 55th percentile (0.80%), a moderate-priority issue whose real-world risk is tempered by its access requirements; it is not confirmed as actively exploited (no CISA KEV listing).

RemediationAI

No vendor-released patch or fixed firmware version is identified in the available data, so operators should treat the device as unpatched and monitor https://www.tenda.com.cn/ for a firmware update or EoL/security notice. Until then, the most effective compensating controls are to disable remote/WAN management and any port-forwarding or UPnP rules that expose the web administration interface to untrusted networks, and to place the router behind a firewall so only trusted LAN clients can reach it - the trade-off is loss of legitimate remote administration. Change default administrative credentials and use unique, strong passwords, since the assessed PR:L vector means an attacker must first obtain low-privilege authenticated access; this reduces but does not eliminate risk where credentials are already weak or shared. Network-segment IoT and guest devices away from the management VLAN to limit who can reach /goform/saveAutoQos, and monitor or filter HTTP requests to that endpoint for abnormally long 'enable' parameter values as a detection measure. Where the device cannot be secured or updated, replacing it with a supported router is the only complete mitigation, accepting the hardware replacement cost.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The affected component is the Auto QoS configuration handler of the Tenda AC7 router firmware, reached through the HTTP POST endpoint /goform/saveAutoQos. User-supplied input in the 'enable' argument is copied into a fixed-size stack buffer without adequate bounds checking, the classic root cause class described by CWE-119 (improper restriction of operations within the bounds of a memory buffer). An attacker-controlled overlong value can overwrite adjacent stack memory, which corrupts control-flow data and can lead to a denial of service (device crash/reboot) or, depending on stack layout and the absence of modern mitigations such as stack canaries or ASLR on this embedded MIPS/ARM platform, to arbitrary code execution with the privileges of the router's web server process. The CPE cpe:2.3:o:tenda:ac7_firmware:15.03.06.44 confirms the firmware image, not the hardware revision, as the vulnerable artifact. The vulnerability was reported through VulDB (CNA) with a public proof-of-concept write-up hosted on GitHub.

Know when Ac7 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (vuldb) PRIMARY 7.4 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
vuln.today AI 8.8 HIGH

Network-reachable management endpoint (AV:N), simple to trigger (AC:L), but requires an authenticated low-privilege session (PR:L); stack overflow yields full code-execution impact (C/I/A:H).

3.1 AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (vuldb).

CVSS VectorVendor: vuldb

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

DescriptionCVE.org

A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.

Executive ViewAI

Why It Matters

Tenda AC7 routers running firmware 15.03.06.44 are affected by a high-severity stack-based buffer overflow that can be triggered through the web management interface, potentially allowing code execution on the device. Exploitation requires authenticated low-privilege access and is typically limited to the local network unless remote management is enabled, but publicly available exploit code exists and no vendor-released patch identified at time of analysis. Leadership should prioritize identifying and isolating these devices, as a compromise could disrupt network availability or provide a foothold for lateral movement.

Business Impact: Medium
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations include disabling WAN/remote management, restricting management interface access to trusted LAN only, enforcing strong unique credentials, monitoring for crafted 'enable' parameter requests to /goform/saveAutoQos, and isolating the device on a separate VLAN or replacing it if isolation is not feasible.

Threat Intelligence Overview

EPSS Score
0.8%
Top 45% exploitable
Prevalence
Medium
popular low-cost consumer SOHO router brand, but single model/firmware
Exploit
POC
Public exploit code exists
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC Yes
EPSS 0.8%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
No
Human Impact
Medium

Priority Score

58
Low Medium High Critical
KEV: 0
EPSS: +1
CVSS: +37
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

Affected Products (CPE)CVE.org

cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*
CVE-2025-29137 CRITICAL POC
9.8 Mar 19

Tenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the form_fast_setting_wifi_set f

CVE-2024-32301 CRITICAL POC
9.8 Apr 17

Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle fun

CVE-2023-41562 CRITICAL POC
9.8 Aug 30

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered

CVE-2023-41559 CRITICAL POC
9.8 Aug 30

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to co

CVE-2023-41558 CRITICAL POC
9.8 Aug 30

Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeC

CVE-2023-41557 CRITICAL POC
9.8 Aug 30

Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter

CVE-2023-41556 CRITICAL POC
9.8 Aug 30

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to co

CVE-2023-41555 CRITICAL POC
9.8 Aug 30

Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasi

CVE-2023-41552 CRITICAL POC
9.8 Aug 30

Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parame

CVE-2023-38937 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC

CVE-2023-38936 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28,

CVE-2023-38933 CRITICAL POC
9.8 Aug 07

Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy