Tenda AC7
CVE-2025-11527
HIGH
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessReach router web interface with low-priv credentials
-
DeliverySend crafted /goform/fast_setting_pppoe_set request
-
ExploitOverflow stack buffer via oversized Password argument
-
ExecutionHijack control flow / execute code
-
ImpactFull compromise of router (C/I/A)
Vulnerability Assessment
| Weakness |
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, buffer size validation
MITRE ATT&CK
2 techniques across 2 tactics: Execution, Privilege Escalation The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Exploitation requires the attacker to reach the device's HTTP management interface and send a request to the /goform/fast_setting_pppoe_set endpoint (the PPPoE quick-setup handler) with an overlong 'Password' parameter. The supplied CVSS vector specifies PR:L, so a low level of privilege (e.g., an authenticated management session) is required - this is the primary limiting factor. Further limiting realistic exposure: only Tenda AC7 firmware 15.03.06.44 is confirmed affected, and consumer routers typically do not expose the web UI to the WAN by default, so practical attacks usually require LAN/management-plane access unless remote administration has been enabled. |
| Impact | The provided CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H, base 7.4) indicates a network-reachable, low-complexity stack buffer overflow that requires low-level privileges (PR:L) and no user interaction, with high impact to confidentiality, integrity and availability but no scope change to adjacent systems (SC:N/SI:N/SA:N). Multiple signals are mixed: a public exploit exists (POC=YES) and the finding is credible, but the vulnerability is NOT in CISA KEV and the EPSS score is only 0.80% (55th percentile), meaning there is no evidence of widespread automated exploitation. The E:P (Proof-of-Concept exploit maturity) in the vector is consistent with the public PoC and reinforces that this is demonstrated-but-not-mass-exploited. Net assessment: this is a genuine, exploitable memory-corruption bug on an internet-of-things consumer router, but it is a moderate priority rather than an emergency - exploitation requires authenticated access (PR:L), it affects a single firmware build, and there is no KEV/active-exploitation signal. Prioritize patching/replacing exposed Tenda AC7 units where the web management interface is reachable by untrusted users, but it does not warrant the same urgency as a KEV-listed unauthenticated RCE. |
| Exploit ScenarioDerived | An attacker with low-privilege access to the Tenda AC7 web management interface (e.g., a logged-in user, or an attacker who has reached the LAN/management plane) sends a crafted request to /goform/fast_setting_pppoe_set with an oversized 'Password' argument. This overflows a fixed-size stack buffer in the PPPoE fast-setup handler, corrupting the stack to crash the device or execute attacker-controlled code with the router's privileges. A public proof-of-concept for this exact endpoint is published on GitHub (noahze01/IoT-vulnerable). |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 08, 2026
Stack-based buffer overflow in Tenda AC7 firmware 15.03.06.44 lets an authenticated remote attacker crash or potentially execute code on the device by sending an overlong 'Password' value to the /goform/fast_setting_pppoe_set (PPPoE quick-setup) HTTP endpoint. The flaw carries a CVSS 4.0 base score of 7.4 (AV:N/AC:L/AT:N/PR:L/UI:N, high C/I/A impact, no scope change), and per the supplied vector the attacker needs a low-privilege session (PR:L) rather than being unauthenticated. Publicly available exploit code exists (a PoC write-up is linked from the NVD references), but there is no confirmed active exploitation (not in CISA KEV); EPSS is 0.80% (roughly the 55th percentile), indicating moderate-but-not-elevated predicted exploitation likelihood.
RemediationAI
No vendor-released patch or fixed firmware version is identified in the available data, so operators should treat mitigation as compensating-control driven until Tenda publishes updated firmware (monitor https://www.tenda.com.cn/ and the VulDB entry https://vuldb.com/?id.327665). Primary compensating control: do not expose the AC7 web management interface to untrusted networks - disable remote/WAN administration and keep the LAN-only management plane behind a trusted segment. Because the assessor's vector is PR:L, an authenticated management session is required, so enforce strong non-default admin credentials, avoid credential reuse, and restrict who can log into the UI. Additional actionable measures with trade-offs: block or filter HTTP requests to the /goform/fast_setting_pppoe_set endpoint at an upstream reverse proxy, WAF, or firewall (may break legitimate PPPoE quick-setup via that UI and requires an inline device); segment the router on an isolated management VLAN so only trusted administrators can reach the form (reduces usability for remote management but cuts the attack surface meaningfully); and if the device is not essential to operations, replace or retire the affected firmware. There is no confirmed workaround inside the vulnerable handler, and patch status is: No vendor-released patch identified at time of analysis.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The affected component is the Tenda AC7 consumer router's HTTP management web server, specifically the handler for /goform/fast_setting_pppoe_set, which processes the PPPoE quick-setup form. The 'Password' parameter is copied into a fixed-length stack buffer without adequate bounds checking, producing a classic stack-based buffer overflow (CWE-119). An attacker who can reach the management interface and submit a crafted request can overwrite adjacent stack memory, which may cause a denial of service (device crash/reset) and, depending on stack layout and mitigations, could support control-flow hijacking for code execution. The vulnerability class is the well-known family of unvalidated CGI/goform parameter handling issues common in embedded router firmware; the CVSS 4.0 vector places it as network-reachable with low attack complexity and no user interaction, with high confidentiality, integrity, and availability impact but no impact to subsequent systems (SC:N/SI:N/SA:N). The CPE cpe:2.3:o:tenda:ac7_firmware:15.03.06.44 identifies the single confirmed affected firmware image.
Know when Ac7 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
Network-reachable goform endpoint (AV:N), trivial oversized-parameter trigger (AC:L), authenticated management access needed (PR:L), no UI; stack overflow yields code execution so C/I/A all High.
Primary rating from Vendor (vuldb).
CVSS VectorVendor: vuldb
DescriptionCVE.org
A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing a manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
Executive ViewAI
Tenda AC7 routers running firmware 15.03.06.44 are affected by a high-severity stack-based buffer overflow that requires authentication and could allow an attacker to crash the device or potentially execute code. While publicly available exploit code exists, no active exploitation has been confirmed (not in CISA KEV), and no vendor-released patch is currently available. Organizations using these devices for remote or branch connectivity should prioritize mitigation to prevent network disruption or unauthorized access.
No vendor patch available; restrict network access to affected devices, enforce strong authentication, segment networks, and monitor for anomalous activity.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.
Affected Products (CPE)CVE.org
More in Ac7 Firmware
View allTenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the form_fast_setting_wifi_set f
Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle fun
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to co
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeC
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to co
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasi
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parame
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28,
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0
NVD
CVE.org
EPSS
GitHub
VulDB
Exploit-DB