Tenda AC7
CVE-2025-11526
HIGH
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessReach router web interface
-
DeliveryAuthenticate with low-privilege credentials
-
ExploitSend crafted request to /goform/WifiMacFilterSet
-
ExecutionOverflow stack buffer via wifi_chkHz
-
ImpactExecute code or crash device
Vulnerability Assessment
| Weakness |
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, buffer size validation
MITRE ATT&CK
2 techniques across 2 tactics: Execution, Privilege Escalation The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Requires network access to the Tenda AC7 web management interface AND a valid low-privilege authenticated session (CVSS PR:L) - it is not anonymous/unauthenticated. The specific trigger is a request to the /goform/WifiMacFilterSet endpoint with an oversized wifi_chkHz argument that overflows a stack buffer. Limiting factors: exploitation is constrained to the exact AC7 firmware 15.03.06.44, requires credentials/an established session, and in typical SOHO deployments the management interface is LAN-facing rather than internet-exposed, so WAN exploitation depends on remote-management being enabled. No user interaction is required (UI:N). |
| Impact | Signals are moderate and internally consistent rather than alarming. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:L/UI:N) with high impact to confidentiality, integrity and availability yields 7.4, reflecting network reachability but requiring at least low-level privileges (PR:L) - i.e. an authenticated session on the router's management interface, not anonymous access. A public POC exists (GitHub, noahze01/IoT-vulnerable), so exploit code is available, but this is NOT the same as active exploitation: the CVE is not listed in CISA KEV. EPSS is low at 0.80% (55th percentile), which is consistent with the PR:L precondition and the niche consumer-router target - meaning widespread automated mass-exploitation is unlikely despite public POC code. The 'E:P' (Proof-of-Concept) in the CVSS 4.0 threat metric aligns with POC availability and the absence of confirmed in-the-wild use. Net assessment: this is a genuine code-execution-class flaw with public exploit code, but the authentication requirement and the limited deployment footprint of a single Tenda SOHO router model make it a moderate, not top-tier, priority for most environments - prioritize where this exact model/firmware is exposed. Note one caveat: CWE-119 and 'stack-based buffer overflow' imply potential arbitrary code execution, but neither the description nor VulDB independently confirms achieved RCE versus crash/DoS - verify the actual impact against the POC. |
| Exploit ScenarioDerived | An attacker with access to the Tenda AC7 web management interface and a valid (low-privilege) session sends a crafted request to /goform/WifiMacFilterSet containing an oversized value in the wifi_chkHz parameter, overflowing a stack buffer. A public proof-of-concept is available, lowering the skill barrier, and a successful overflow can crash the device or potentially execute attacker-controlled code on the router. Because PR:L is required, the attacker must first reach and authenticate to the management interface, which in typical deployments is LAN-facing. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 08, 2026
Stack-based buffer overflow in the Tenda AC7 router (firmware 15.03.06.44) lets a network-reachable, authenticated attacker corrupt memory and potentially execute code by sending an oversized wifi_chkHz value to the /goform/WifiMacFilterSet handler. Exploitation requires a valid low-privilege session on the web management interface (CVSS PR:L) and no user interaction (UI:N); publicly available exploit code exists for this exact firmware, though there is no evidence of active exploitation (not in CISA KEV). EPSS is low at roughly 0.80% (55th percentile), and overall the signal set is moderate and internally consistent rather than alarming, with real-world exposure largely limited to devices whose management interface is reachable and whose remote-management option is enabled.
RemediationAI
No vendor-released patch identified at time of analysis: the supplied references include the Tenda homepage but no advisory or patched firmware version, so the exact fix build is unconfirmed and administrators should check https://www.tenda.com.cn/ directly for an AC7 firmware update before assuming one exists. Until a fixed build is available, apply compensating controls: disable remote/WAN management so the goform interface is only reachable from the trusted LAN (trade-off: loses off-site administration), block the management port and /goform/* paths at the network perimeter or via router firewall rules (trade-off: may require rule maintenance and can interfere with legitimate local management tools), enforce strong unique admin credentials to raise the PR:L bar (trade-off: does not stop a compromised session), and isolate the router's management interface on a segregated VLAN or restrict source IPs that may reach it (trade-off: added topology complexity). Replacing the AC7 with a supported model or applying an alternative open-source firmware is a strong option if Tenda does not ship a fix, since the vulnerable endpoint is part of the stock web management daemon.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The flaw is a memory-safety defect in the AC7's embedded web server handling of the goform interface. The /goform/WifiMacFilterSet endpoint parses the wifi_chkHz parameter and copies it into a fixed-size stack buffer without validating length, producing an out-of-bounds write that maps to CWE-119 (improper restriction of operations within the bounds of a memory buffer) and, more specifically, the classic stack-based buffer overflow pattern. Tenda goform endpoints are handled by the router's HTTP daemon on the management interface, so an attacker who can reach that interface can drive the vulnerable function directly. Per the CPE (cpe:2.3:o:tenda:ac7_firmware:15.03.06.44), the exact and only confirmed affected build is AC7 firmware 15.03.06.44; the CVSS 4.0 vector confirms network attack (AV:N), low privileges (PR:L), no user interaction (UI:N), and an exploit proof-of-concept maturity metric (E:P), matching the public GitHub write-up. The associated CVSS 3.1 reassessment (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) likewise treats the endpoint as requiring an authenticated session, consistent with the PR:L rating rather than anonymous access.
Know when Ac7 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
Network-reachable endpoint (AV:N) with no interaction (UI:N) but requiring an authenticated session (PR:L); stack overflow in router firmware plausibly yields full code execution, so C/I/A:H.
Primary rating from Vendor (vuldb).
CVSS VectorVendor: vuldb
DescriptionCVE.org
A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing a manipulation of the argument wifi_chkHz results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used.
Executive ViewAI
The Tenda AC7 router running firmware 15.03.06.44 is affected by a high-severity vulnerability that enables an authenticated attacker with network access to the management interface to potentially execute arbitrary code. Organizations using these devices in exposed configurations-especially with remote management enabled-face risks of network compromise, unauthorized access, and data interception. Leadership should prioritize mitigating exposure while a vendor patch remains unavailable.
Disable remote management; restrict management interface access to trusted networks via firewall rules; enforce strong, unique credentials; monitor for anomalous requests to /goform/WifiMacFilterSet; and segment affected devices to limit potential impact.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.
Affected Products (CPE)CVE.org
More in Ac7 Firmware
View allTenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the form_fast_setting_wifi_set f
Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle fun
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to co
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeC
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to co
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasi
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parame
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28,
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0
NVD
CVE.org
EPSS
GitHub
VulDB
Exploit-DB