Hitachi Energy TropOS
CVE-2025-1038
HIGH
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessObtain high-privilege web admin credentials
-
DeliveryOpen Diagnostics Tools page
-
ExploitInject OS commands into unvalidated input field
-
ExecutionInvoke SUID applications to escalate
-
ImpactGain root on TropOS device
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization OS command sanitization, avoid shell exec
MITRE ATT&CK
2 techniques across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Exploitation requires an authenticated session with HIGH privileges (administrative access) to the TropOS 4th Gen web-based configuration utility, and access to the specific 'Diagnostics Tools' page whose input fields are not validated. Escalation to root depends on the presence of exploitable set-uid (SUID) applications on the device, which the injected commands invoke. Limiting factors: the attacker must already hold high-privilege web credentials (PR:H), a specific attack precondition applies (AT:P), and the issue is confined to TropOS 4th Gen devices - this is a privilege-escalation / post-authentication flaw, not remote unauthenticated compromise. |
| Impact | This is an authenticated, high-privilege OS command injection (CWE-78) in the Diagnostics Tools page of the Hitachi Energy TropOS 4th Gen web configuration utility, escalating to root via SUID binaries. The CVSS 4.0 vector (AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H, score 7.5 HIGH) shows full confidentiality/integrity/availability impact over the network, but the critical mitigating signal is PR:H - the attacker must already hold high-privilege (administrative) access to the device, and AT:P indicates a specific attack precondition must be met. Supporting signals point to LOW real-world priority: EPSS is 0.32% (23rd percentile), this CVE is NOT in CISA KEV, and no public exploit code is referenced. The signals are internally consistent - a high-impact but access-gated flaw with no evidence of exploitation. The practical risk is post-compromise privilege escalation / integrity loss on already-administered industrial networking gear, not opportunistic remote takeover. Priority should be driven by the criticality of the TropOS deployment (utility/ICS environments) rather than by broad exploitation likelihood. |
| Exploit ScenarioDerived | An attacker who has already obtained high-privilege (administrative) credentials to the TropOS web configuration utility navigates to the Diagnostics Tools page and submits crafted input into a field that is passed unsanitized to the underlying command shell. The injected commands invoke existing SUID applications on the device to escalate from the administrative web context to full root on the TropOS 4th Gen device. No public exploit identified at time of analysis; exploitation requires prior privileged access. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 08, 2026
OS command injection in Hitachi Energy TropOS 4th Gen web configuration utility allows an authenticated high-privilege user to inject shell commands through the Diagnostics Tools page and abuse set-uid applications to escalate to root on the device. The flaw requires administrative web access to TropOS 4th Gen and is a post-authentication privilege-escalation issue, not unauthenticated remote compromise. The provided intelligence shows EPSS 0.32% (low), no CISA KEV entry, and no public exploit identified at time of analysis.
RemediationAI
Apply the fixed firmware or software version specified in the Hitachi Energy advisory for CVE-2025-1038 at https://publisher.hitachienergy.com/preview?DocumentID=8DBD000214&LanguageCode=en&DocumentPartId=&Action=Launch; the provided input does not enumerate an exact fixed version, so treat that advisory as authoritative. Until patching, restrict access to the TropOS 4th Gen web configuration utility and especially the Diagnostics Tools page to fully trusted high-privilege administrators, enforce unique admin accounts with auditing, and monitor for unexpected shell or SUID-related activity. If the Diagnostics Tools page is not required, disable or block access to it at the management interface, accepting reduced troubleshooting capability; network segmentation and management-plane ACLs reduce exposure but do not eliminate the post-authentication escalation risk because a high-privileged attacker can still use legitimate access. No KEV active exploitation or public proof-of-concept was identified in the provided data.
Affected ProductsAI
This affects Hitachi Energy TropOS 4th Gen devices running the web-based configuration utility and exposing the Diagnostics Tools page. The provided data does not list exact firmware version ranges or CPE identifiers, so the vendor advisory at publisher.hitachienergy.com (DocumentID=8DBD000214) should be consulted for the precise affected builds. The independent assessment confines the issue to TropOS 4th Gen devices, meaning other TropOS generations are not confirmed as affected by this CVE.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The root cause is CWE-78 improper neutralization of special elements used in an OS command, where the Diagnostics Tools page passes user-controlled input to a device command shell without adequate validation. The affected technology is the web-based configuration utility of Hitachi Energy TropOS 4th Gen devices; the CVSS 4.0 vector is AV:N/AC:L/AT:P/PR:H/UI:N with high confidentiality, integrity, and availability impact, and the independent assessment uses CVSS 3.1 AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H. Because the attacker must already hold high-privilege web credentials and a specific attack precondition applies, this is best characterized as authenticated command injection that can invoke SUID binaries to gain root, rather than a pre-auth or wormable flaw. No CPE strings were supplied, but the product family is TropOS 4th Gen.
Know when Hitachi Energy gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Network-reachable web utility (AV:N) but requires high-privilege admin auth (PR:H) and a specific precondition mapped to AC:H; full root compromise yields C:H/I:H/A:H.
Primary rating from Vendor (hitachienergy).
CVSS VectorVendor: hitachienergy
DescriptionCVE.org
The “Diagnostics Tools” page of the web-based configuration utility does not properly validate user-controlled input, allowing an authenticated user with high privileges to inject commands into the command shell of the TropOS 4th Gen device. The injected commands can be exploited to execute several set-uid (SUID) applications to ultimately gain root access to the TropOS device.
Executive ViewAI
Hitachi Energy TropOS 4th Gen field devices carry an unpatched flaw in the web configuration utility that lets someone who already holds administrative web credentials escalate to full root control of the device. Because these are utility-grade communications platforms typically deployed in operational technology networks, a successful escalation could give an intruder or a disgruntled insider the ability to alter, disrupt, or persist on grid and industrial communications infrastructure that is otherwise difficult to monitor. Leadership should care less about broad internet-facing exposure - the prerequisites are significant and exploitation activity is not currently observed - and more about insider risk, weak administrative credential hygiene, and the absence of a vendor remedy on the near-term horizon.
No vendor-released patch identified at time of analysis. Interim mitigations: restrict web configuration utility access to a hardened management network or jump host; enforce least privilege and multi-factor authentication for administrative accounts; rotate administrative credentials; disable the web utility on devices that do not require it; monitor and alert on administrative logins and Diagnostics Tools usage; open a vendor support case for remediation guidance and tracking.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
OS command injection occurs when an application passes unsanitized user input directly into system shell commands.
More in Hitachi Energy
View allUnauthenticated network attackers can exploit a directory traversal flaw in the file-upload feature of Hitachi Energy RT
Unauthenticated attackers able to reach the firmware-update endpoint of Hitachi Energy RTU500 series CMU devices can upl
Command injection in the Logging page of the web-based configuration utility shipped with Hitachi Energy TropOS 4th Gen
NULL pointer dereference in Hitachi Energy RTU500 series CMU Firmware allows an adjacent low-privileged attacker to cras
Remote attackers without authentication can access the HTTPPublishAdapterTestServlet on Hitachi Energy Asset Suite deplo
Privilege escalation in Hitachi Energy MicroSCADA SYS600 allows any user with access to the engineering tools to elevate
Broken application-layer authentication in Hitachi Energy MicroSCADA SYS600 allows any user with an operating system acc
Improper privilege management (CWE-269) in the Hitachi Energy TropOS 4th Gen device allows an authenticated user who can
Cleartext-transmission exposure in Hitachi Energy PROMOD V allows a network man-in-the-middle to intercept or read sensi
The Hitachi Energy RTU500 series CMU web application fails to enforce proper authorization on its reset endpoint, allowi
Heap-based buffer overflow in Hitachi Energy MACH HiDraw's XML parser allows a low-privileged, locally authenticated att
Denial of service in Hitachi Energy RTU500 Series CMU firmware allows an unauthenticated remote attacker to crash the IE
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB