Skip to main content

Rockwell CVE-2024-6079

MEDIUM
Externally Controlled Reference to a Resource in Another Sphere (CWE-610)
2024-08-13 PSIRT@rockwellautomation.com
5.4
CVSS 4.0 · Vendor: rockwellautomation
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V4 - API and Web Service External resource reference control
Impact

CVSS score of 5.4 (MEDIUM). Attack characteristics: local attack vector, high complexity, low privileges required, user interaction required.

Exploit ScenarioDerived

Successful exploitation could compromise the medium-severity affected system.

This Month Plan within 30 days. Why: MEDIUM severity (CVSS 4.0-6.9).
No patch listed yet 0.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

A vulnerability exists in the Rockwell Automation Emulate3D™, which could be leveraged to execute a DLL Hijacking attack. Rated medium severity (CVSS 5.4). No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Affected ProductsAI

See vendor advisory for affected versions.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified under CWE-610. A vulnerability exists in the Rockwell Automation Emulate3D™, which could be leveraged to execute a DLL Hijacking attack. The application loads shared libraries, which are readable and writable by any user. If exploited, a malicious user could leverage a malicious dll and perform a remote code execution attack.

Know when Rockwell gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (rockwellautomation) PRIMARY 5.4 MEDIUM
CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (rockwellautomation) · only source for this CVE.

CVSS VectorVendor: rockwellautomation

Attack Vector
Local
Attack Complexity
High
Attack Requirements
None
Privileges Required
Low
User Interaction
Active
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

DescriptionCVE.org

A vulnerability exists in the Rockwell Automation Emulate3D™, which could be leveraged to execute a DLL Hijacking attack. The application loads shared libraries, which are readable and writable by any user. If exploited, a malicious user could leverage a malicious dll and perform a remote code execution attack.

Threat Intelligence Overview

EPSS Score
0.2%
Top 88% exploitable
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity MEDIUM
CISA KEV No
Public POC No
EPSS 0.2%
Patch available No
Active threat No
Deciding rule
MEDIUM severity (CVSS 4.0-6.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Defer
Exploitation· derived
None
System Exposure· derived
Small
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

27
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +27
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

CVE-2020-12028 HIGH POC
8.1 Jul 20

In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to int

CVE-2020-12029 HIGH POC
7.8 Jul 20

All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. Rated high s

CVE-2023-2917 CRITICAL POC
9.8 Aug 17

The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability. Rated critical

CVE-2023-27855 CRITICAL POC
9.8 Mar 22

In affected versions, a path traversal exists when processing a message in Rockwell Automation's ThinManager ThinServer.

CVE-2018-14829 CRITICAL POC
9.8 Sep 20

Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. Rated critical severity (CVSS 9.8), this vulnerability is

CVE-2017-7924 HIGH POC
7.5 Sep 20

An Improper Input Validation issue was discovered in Rockwell Automation MicroLogix 1100 controllers 1763-L16BWA, 1763-L

CVE-2016-5645 HIGH
7.3 Aug 24

Rockwell Automation MicroLogix 1400 PLC 1766-L32BWA, 1766-L32AWA, 1766-L32BXB, 1766-L32BWAA, 1766-L32AWAA, and 1766-L32B

CVE-2023-2915 CRITICAL POC
9.1 Aug 17

The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability, Due to imprope

CVE-2012-6437 CRITICAL
9.8 Jan 24

The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware imag

CVE-2018-19616 HIGH POC
8.1 Dec 26

An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. Rated high severity (CVSS 8.1), this vul

CVE-2023-27856 HIGH POC
7.5 Mar 22

In affected versions, path traversal exists when processing a message of type 8 in Rockwell Automation's ThinManager Thi

CVE-2020-6085 HIGH POC
7.5 Oct 19

An exploitable denial of service vulnerability exists in the ENIP Request Path Logical Segment functionality of Allen-Br

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy