7Kt Pac1260 Data Manager Firmware
CVE-2024-41790
CRITICAL
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Lifecycle Timeline
2DescriptionCVE.org
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the region parameter in specific POST requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.
AnalysisAI
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). Rated critical severity (CVSS 9.4), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as OS Command Injection (CWE-78), which allows attackers to execute arbitrary operating system commands on the host. A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the region parameter in specific POST requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges. Affected products include: Siemens 7Kt Pac1260 Data Manager Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Avoid passing user input to shell commands. Use language-specific APIs instead of shell execution. Apply strict input validation with allowlists.
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). Rated critical severity (CVSS 10
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). Rated critical severity (CVSS 9.
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). Rated critical severity (CVSS 9.
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). Rated critical severity (CVSS 9.
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). Rated high severity (CVSS 7.7),
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). Rated medium severity (CVSS 6.9)
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). Rated medium severity (CVSS 6.9)
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). Rated medium severity (CVSS 6.9)
Same weakness CWE-78 – OS Command Injection
View allSame technique Command Injection
View allShare
External POC / Exploit Code
Leaving vuln.today