Skip to main content

W15e Firmware CVE-2024-4115

HIGH
Stack-based Buffer Overflow (CWE-121)
2024-04-24 cna@vuldb.com
8.8
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Stack buffer bounds checking
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 8.8 (HIGH). Attack characteristics: network attack vector, low complexity, low privileges required, no user interaction not required. Public proof-of-concept exploit code is available.

Exploit ScenarioDerived

This vulnerability can be exploited remotely over the network. Successful exploitation could compromise the high-severity affected system.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 1.7% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified under CWE-121. A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. Affected is the function formAddDnsForward of the file /goform/AddDnsForward. The manipulation of the argument DnsForwardRule leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261858 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Affected products include: Tenda W15E Firmware.

Know when W15e Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionNVD

A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. Affected is the function formAddDnsForward of the file /goform/AddDnsForward. The manipulation of the argument DnsForwardRule leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261858 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Threat Intelligence Overview

EPSS Score
1.7%
Top 26% exploitable
Exploit
POC
Public exploit code exists
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC Yes
EPSS 1.7%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

66
Low Medium High Critical
KEV: 0
EPSS: +2
CVSS: +44
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

A stack-based buffer overflow occurs when a program writes more data to a buffer located on the stack than it was allocated to hold.

Affected Products (CPE)NVD

cpe:2.3:o:tenda:w15e_firmware:15.11.0.14:*:*:*:*:*:*:*
CVE-2023-27063 CRITICAL POC
9.8 Mar 13

Tenda V15V1.0 V15.11.0.14(1521_3190_1058) was discovered to contain a buffer overflow vulnerability via the DNSDomainNam

CVE-2023-27061 CRITICAL POC
9.8 Mar 13

Tenda V15V1.0 V15.11.0.14(1521_3190_1058) was discovered to contain a buffer overflow vulnerability via the wifiFilterLi

CVE-2022-42058 CRITICAL POC
9.8 Nov 15

Tenda AC1200 Router Model W15Ev2 V15.11.0.10(1576) was discovered to contain a stack overflow via the setRemoteWebManage

CVE-2024-4127 HIGH POC
8.8 Apr 24

A vulnerability was found in Tenda W15E 15.11.0.14. Rated high severity (CVSS 8.8), this vulnerability is remotely explo

CVE-2024-4126 HIGH POC
8.8 Apr 24

A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. Rated high severity (CVSS 8.8), this vuln

CVE-2024-4125 HIGH POC
8.8 Apr 24

A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. Rated high severity (CVSS 8.8), this

CVE-2024-4124 HIGH POC
8.8 Apr 24

A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. Rated high severity (CVSS 8.8), t

CVE-2024-4123 HIGH POC
8.8 Apr 24

A vulnerability, which was classified as critical, has been found in Tenda W15E 15.11.0.14. Rated high severity (CVSS 8.

CVE-2024-4122 HIGH POC
8.8 Apr 24

A vulnerability classified as critical was found in Tenda W15E 15.11.0.14. Rated high severity (CVSS 8.8), this vulnerab

CVE-2024-4121 HIGH POC
8.8 Apr 24

A vulnerability classified as critical has been found in Tenda W15E 15.11.0.14. Rated high severity (CVSS 8.8), this vul

CVE-2024-4120 HIGH POC
8.8 Apr 24

A vulnerability was found in Tenda W15E 15.11.0.14. Rated high severity (CVSS 8.8), this vulnerability is remotely explo

CVE-2024-4119 HIGH POC
8.8 Apr 24

A vulnerability was found in Tenda W15E 15.11.0.14. Rated high severity (CVSS 8.8), this vulnerability is remotely explo

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy