Skip to main content

F1202 Firmware CVE-2024-3876

HIGH
Stack-based Buffer Overflow (CWE-121)
2024-04-16 cna@vuldb.com
8.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Apr 16, 2024 - 18:15 nvd
HIGH 8.8

DescriptionNVD

A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

AnalysisAI

A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-121. A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Affected products include: Tenda F1202 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

CVE-2024-30635 CRITICAL POC
9.8 Mar 29

Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability located in the funcpara1 parameter in the formSetCfm funct

CVE-2023-38939 CRITICAL POC
9.8 Aug 07

Tenda F1202 V1.2.0.9 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the mit_ssid parameter in the f

CVE-2023-38938 CRITICAL POC
9.8 Aug 07

Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow vi

CVE-2023-38932 CRITICAL POC
9.8 Aug 07

Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow vi

CVE-2023-37723 CRITICAL POC
9.8 Jul 14

Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter

CVE-2023-37722 CRITICAL POC
9.8 Jul 14

Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter

CVE-2023-37721 CRITICAL POC
9.8 Jul 14

Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter

CVE-2023-37719 CRITICAL POC
9.8 Jul 14

Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter

CVE-2023-37718 CRITICAL POC
9.8 Jul 14

Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter

CVE-2023-37717 CRITICAL POC
9.8 Jul 14

Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were

CVE-2023-37716 CRITICAL POC
9.8 Jul 14

Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were

CVE-2023-37715 CRITICAL POC
9.8 Jul 14

Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter

Share

CVE-2024-3876 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy