Skip to main content

W20e Firmware CVE-2024-3874

HIGH
Stack-based Buffer Overflow (CWE-121)
2024-04-16 cna@vuldb.com
8.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Apr 16, 2024 - 16:15 nvd
HIGH 8.8

DescriptionNVD

A vulnerability was found in Tenda W20E 15.11.0.6. It has been declared as critical. This vulnerability affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260908. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

AnalysisAI

A vulnerability was found in Tenda W20E 15.11.0.6. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-121. A vulnerability was found in Tenda W20E 15.11.0.6. It has been declared as critical. This vulnerability affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260908. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Affected products include: Tenda W20E Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

CVE-2026-24107 CRITICAL POC
9.8 Mar 02

Tenda W20E router has a code injection vulnerability in usbPartitionName parameter allowing unauthenticated remote code

CVE-2026-24112 CRITICAL POC
9.8 Mar 02

Tenda W20E has a ninth buffer overflow in yet another CGI endpoint.

CVE-2026-24110 CRITICAL POC
9.8 Mar 02

Tenda W20E has an eighth buffer overflow in addDhcpRules parameter.

CVE-2026-24115 CRITICAL POC
9.8 Mar 02

Tenda W20E has a seventh buffer overflow in gstup parameter handling.

CVE-2026-24114 CRITICAL POC
9.8 Mar 02

Tenda W20E has a sixth buffer overflow in pPortMapIndex parameter validation.

CVE-2026-24113 CRITICAL POC
9.8 Mar 02

Tenda W20E has a fifth buffer overflow.

CVE-2026-24111 CRITICAL POC
9.8 Mar 02

Tenda W20E has a fourth buffer overflow vulnerability.

CVE-2026-24109 CRITICAL POC
9.8 Mar 02

Tenda W20E has a third buffer overflow in a different CGI parameter.

CVE-2026-24108 CRITICAL POC
9.8 Mar 02

Tenda W20E has a buffer overflow — second of eight critical vulnerabilities in this router firmware.

CVE-2023-26806 CRITICAL POC
9.8 Mar 19

Tenda W20E v15.11.0.6(US_W20EV4.0br_v15.11.0.6(1068_1546_841 is vulnerable to Buffer Overflow via function formSetSysTim

CVE-2023-26805 CRITICAL POC
9.8 Mar 19

Tenda W20E v15.11.0.6 (US_W20EV4.0br_v15.11.0.6(1068_1546_841)_CN_TDC) is vulnerable to Buffer Overflow via function for

CVE-2022-40868 CRITICAL POC
9.8 Sep 23

Tenda W20E router V15.11.0.6 (US_W20EV4.0br_V15.11.0.6(1068_1546_841)_CN_TDC) contains a stack overflow vulnerability in

Share

CVE-2024-3874 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy