Cp900L Firmware
CVE-2024-35399
HIGH
Vulnerability Assessment
| Weakness |
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Stack buffer bounds checking
MITRE ATT&CK
1 technique across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 8.8 (HIGH). Attack characteristics: adjacent network attack vector, low complexity, no privileges required, no user interaction not required. EPSS exploitation probability: 0.48%. |
| Exploit ScenarioDerived | Successful exploitation could compromise the high-severity affected system. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
TOTOLINK CP900L v4.1.5cu.798_B20221228 was discovered to contain a stack overflow via the password parameter in the function loginAuth. Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified under CWE-121. TOTOLINK CP900L v4.1.5cu.798_B20221228 was discovered to contain a stack overflow via the password parameter in the function loginAuth Affected products include: Totolink Cp900L Firmware.
Severity by source
AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from Vendor (mitre) · only source for this CVE.
CVSS VectorVendor: mitre
DescriptionCVE.org
TOTOLINK CP900L v4.1.5cu.798_B20221228 was discovered to contain a stack overflow via the password parameter in the function loginAuth
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.
A stack-based buffer overflow occurs when a program writes more data to a buffer located on the stack than it was allocated to hold.
Affected Products (CPE)CVE.org
More in Cp900L Firmware
View allTOTOLINK CP900L v4.1.5cu.798_B20221228 weas discovered to contain a command injection vulnerability in the NTPSyncWithHo
TOTOLINK CP900L v4.1.5cu.798_B20221228 was discovered to contain a stack overflow via the desc parameter in the function
TOTOLINK CP900L v4.1.5cu.798_B20221228 was discovered to contain a hardcoded password for telnet in /web_cste/cgi-bin/pr
TOTOLINK CP900L v4.1.5cu.798_B20221228 was discovered to contain a hardcoded password vulnerability in /etc/shadow.sampl
TOTOLINK CP900L v4.1.5cu.798_B20221228 was discovered to contain a command injection vulnerability via the FileName para
TOTOLINK CP900L v4.1.5cu.798_B20221228 was discovered to contain a stack overflow via the desc parameter in the function
TOTOLINK CP900L v4.1.5cu.798_B20221228 was discovered to contain a stack overflow via the desc parameter in the function
NVD
CVE.org
EPSS
GitHub
VulDB
Exploit-DB