Skip to main content

F1203 Firmware CVE-2024-32312

MEDIUM
Stack-based Buffer Overflow (CWE-121)
2024-04-17 cve@mitre.org
5.7
CVSS 3.1 · Vendor: mitre
Share

Severity by source

Vendor (mitre) PRIMARY
5.7 MEDIUM
AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H

Primary rating from Vendor (mitre) · only source for this CVE.

CVSS VectorVendor: mitre

CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
Attack Vector
Adjacent
Attack Complexity
Low
Privileges Required
None
User Interaction
Required
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

Lifecycle Timeline

1
CVE Published
Apr 17, 2024 - 13:15 cve.org
MEDIUM 5.7

DescriptionCVE.org

Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the adslPwd parameter of the formWanParameterSetting function.

AnalysisAI

Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the adslPwd parameter of the formWanParameterSetting function. Rated medium severity (CVSS 5.7), this vulnerability is no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-121. Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the adslPwd parameter of the formWanParameterSetting function. Affected products include: Tenda F1203 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

CVE-2023-38940 CRITICAL POC
9.8 Aug 07

Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid

CVE-2023-38936 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28,

CVE-2023-38934 CRITICAL POC
9.8 Aug 07

Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the device

CVE-2023-38933 CRITICAL POC
9.8 Aug 07

Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0

CVE-2023-38931 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1

CVE-2023-38930 CRITICAL POC
9.8 Aug 07

Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775)

CVE-2022-46538 CRITICAL POC
9.8 Dec 20

Tenda F1203 V2.0.1.6 was discovered to contain a command injection vulnerability via the mac parameter at /goform/WriteF

CVE-2024-2979 HIGH POC
8.8 Mar 27

A vulnerability classified as critical was found in Tenda F1203 2.0.1.6. Rated high severity (CVSS 8.8), this vulnerabil

CVE-2024-2978 HIGH POC
8.8 Mar 27

A vulnerability classified as critical has been found in Tenda F1203 2.0.1.6. Rated high severity (CVSS 8.8), this vulne

CVE-2024-2977 HIGH POC
8.8 Mar 27

A vulnerability was found in Tenda F1203 2.0.1.6. Rated high severity (CVSS 8.8), this vulnerability is remotely exploit

CVE-2024-2976 HIGH POC
8.8 Mar 27

A vulnerability was found in Tenda F1203 2.0.1.6. Rated high severity (CVSS 8.8), this vulnerability is remotely exploit

CVE-2024-32310 HIGH POC
8.0 Apr 17

Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the PPW parameter of the fromWizardHandle fu