1DescriptionCVE.org
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected application contains a type confusion vulnerability while parsing IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21562)
AnalysisAI
A vulnerability has been identified in Simcenter Femap (All versions < V2406). Rated high severity (CVSS 7.3), this vulnerability is no authentication required. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Access of Resource Using Incompatible Type (Type Confusion) (CWE-843), which allows attackers to execute arbitrary code by exploiting type confusion in the application. A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected application contains a type confusion vulnerability while parsing IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21562) Affected products include: Siemens Ps\/Iges Parasolid Translator, Siemens Simcenter Femap.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Enforce strict type checking, use type-safe languages, validate object types before operations.
More in Simcenter Femap
View allOut-of-bounds read during BMP file parsing in Siemens Simcenter Femap (all versions prior to V2606.0001) enables code ex
Out-of-bounds read in Siemens Simcenter Femap's BMP file parser exposes all versions prior to V2606.0001 to code executi
Arbitrary code execution in Siemens Simcenter Femap (all versions before V2512.0003) arises from a heap-based memory cor
A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.2). Rated high severity (CVSS 8.8), this
Improper TLS certificate validation in Siemens Software Center, Simcenter 3D, Simcenter Femap, Simcenter STAR-CCM+, Soli
Arbitrary code execution in Simcenter Femap and Nastran versions prior to V2512 results from an out-of-bounds write flaw
Code execution in Simcenter Femap and Nastran versions prior to V2512 results from an out-of-bounds read flaw triggered
Heap-based buffer overflow in Simcenter Femap and Nastran versions prior to V2512 allows local attackers to achieve arbi
Out-of-bounds read in Simcenter Femap and Nastran versions prior to V2512 during NDB file parsing enables local code exe
Simcenter Femap and Nastran versions prior to 2512 are vulnerable to out-of-bounds memory reads when processing maliciou
Arbitrary code execution in Simcenter Femap and Nastran versions prior to 2512 results from an out-of-bounds read when p
A vulnerability has been identified in Simcenter Femap (All versions < V2306.0000). Rated high severity (CVSS 7.8), this