Fh1203 Firmware
CVE-2024-30597
MEDIUM
Severity by source
AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Primary rating from Vendor (mitre) · only source for this CVE.
CVSS VectorVendor: mitre
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Lifecycle Timeline
1DescriptionCVE.org
Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability in the security parameter of the formWifiBasicSet function.
AnalysisAI
Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability in the security parameter of the formWifiBasicSet function. Rated medium severity (CVSS 6.5), this vulnerability is no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Technical ContextAI
This vulnerability is classified under CWE-121. Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability in the security parameter of the formWifiBasicSet function. Affected products include: Tenda Fh1203 Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
More in Fh1203 Firmware
View allTenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the schedStartTime parameter of the setSchedWifi function. R
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28,
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the device
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the entrys parameter in the fromAddressNat function
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromAddressNat function.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetClientState fu
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan func
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName fun
Same weakness CWE-121 – Stack-based Buffer Overflow
View allSame technique Buffer Overflow
View allShare
External POC / Exploit Code
Leaving vuln.today