Skip to main content

Fh1203 Firmware CVE-2024-2994

HIGH
Stack-based Buffer Overflow (CWE-121)
2024-03-27 cna@vuldb.com
8.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Mar 27, 2024 - 20:15 nvd
HIGH 8.8

DescriptionNVD

A vulnerability was found in Tenda FH1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258163. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

AnalysisAI

A vulnerability was found in Tenda FH1203 2.0.1.6. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-121. A vulnerability was found in Tenda FH1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258163. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Affected products include: Tenda Fh1203 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

CVE-2024-30602 CRITICAL POC
9.8 Mar 28

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the schedStartTime parameter of the setSchedWifi function. R

CVE-2023-38940 CRITICAL POC
9.8 Aug 07

Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid

CVE-2023-38936 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28,

CVE-2023-38934 CRITICAL POC
9.8 Aug 07

Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the device

CVE-2023-38933 CRITICAL POC
9.8 Aug 07

Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0

CVE-2023-38931 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1

CVE-2023-37707 CRITICAL POC
9.8 Jul 10

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function.

CVE-2023-37706 CRITICAL POC
9.8 Jul 10

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the entrys parameter in the fromAddressNat function

CVE-2023-37705 CRITICAL POC
9.8 Jul 10

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromAddressNat function.

CVE-2023-37704 CRITICAL POC
9.8 Jul 10

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetClientState fu

CVE-2023-37703 CRITICAL POC
9.8 Jul 10

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan func

CVE-2023-37702 CRITICAL POC
9.8 Jul 10

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName fun

Share

CVE-2024-2994 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy