Skip to main content

CVE-2024-22387

MEDIUM
External Control of Critical State Data (CWE-642)
2024-07-11 disclosures@gallagher.com
6.8
CVSS 3.1 · Vendor: gallagher
Share

Severity by source

Vendor (gallagher) PRIMARY
6.8 MEDIUM
AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:H/A:H

Primary rating from Vendor (gallagher) · only source for this CVE.

CVSS VectorVendor: gallagher

CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:H/A:H
Attack Vector
Network
Attack Complexity
High
Privileges Required
None
User Interaction
Required
Scope
Unchanged
Confidentiality
None
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Jul 11, 2024 - 03:15 cve.org
MEDIUM 6.8

DescriptionCVE.org

External Control of Critical State Data (CWE-642) in the Controller 6000 and Controller 7000 diagnostic web interface allows an authenticated user to modify device I/O connections leading to unexpected behavior that in some circumstances could compromise site physical security controls. Gallagher recommend the diagnostic web page is not enabled (default is off) unless advised by Gallagher Technical support. This interface is intended only for diagnostic purposes.

This issue affects: Gallagher Controller 6000 and 7000

9.10 prior to vCR9.10.240520a (distributed in 9.10.1268(MR1)), 9.00 prior to vCR9.00.240521a (distributed in 9.00.1990(MR3)), 8.90 prior to vCR8.90.240520a (distributed in 8.90.1947 (MR4)), 8.80 prior to vCR8.80.240520a (distributed in 8.80.1726 (MR5)), 8.70 prior to vCR8.70.240520a (distributed in 8.70.2824 (MR7)), all versions of 8.60 and prior.

AnalysisAI

External Control of Critical State Data (CWE-642) in the Controller 6000 and Controller 7000 diagnostic web interface allows an authenticated user to modify device I/O connections leading to. Rated medium severity (CVSS 6.8), this vulnerability is remotely exploitable, no authentication required. No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-642. External Control of Critical State Data (CWE-642) in the Controller 6000 and Controller 7000 diagnostic web interface allows an authenticated user to modify device I/O connections leading to unexpected behavior that in some circumstances could compromise site physical security controls. Gallagher recommend the diagnostic web page is not enabled (default is off) unless advised by Gallagher Technical support. This interface is intended only for diagnostic purposes. This issue affects: Gallagher Controller 6000 and 7000 9.10 prior to vCR9.10.240520a (distributed in 9.10.1268(MR1)), 9.00 prior to vCR9.00.240521a (distributed in 9.00.1990(MR3)), 8.90 prior to vCR8.90.240520a (distributed in 8.90.1947 (MR4)), 8.80 prior to vCR8.80.240520a (distributed in 8.80.1726 (MR5)), 8.70 prior to vCR8.70.240520a (distributed in 8.70.2824 (MR7)), all versions of 8.60 and prior.

Affected ProductsAI

See vendor advisory for affected versions.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Share

CVE-2024-22387 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy