Skip to main content

Junos CVE-2024-21605

HIGH
Exposure of Resource to Wrong Sphere (CWE-668)
2024-04-12 sirt@juniper.net
7.1
CVSS 4.0 · Vendor: juniper
Share

Severity by source

Vendor (juniper) PRIMARY
7.1 HIGH
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from Vendor (juniper) · only source for this CVE.

CVSS VectorVendor: juniper

CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Adjacent
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
X

Lifecycle Timeline

1
CVE Published
Apr 12, 2024 - 15:15 cve.org
HIGH 7.1

DescriptionCVE.org

An Exposure of Resource to Wrong Sphere vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on SRX 300 Series allows an unauthenticated, adjacent attacker to cause a Denial of Service (DoS).

Specific valid link-local traffic is not blocked on ports in STP blocked state but is instead sent to the control plane of the device. This leads to excessive resource consumption and in turn severe impact on all control and management protocols of the device.

This issue affects Juniper Networks Junos OS:

  • 21.2 version 21.2R3-S3 and later versions earlier than 21.2R3-S6;
  • 22.1 version 22.1R3 and later versions earlier than 22.1R3-S4;
  • 22.2 version

22.2R2

and later versions earlier than 22.2R3-S2;

  • 22.3 version

22.3R2

and later versions earlier than 22.3R3-S1;

  • 22.4 versions earlier than 22.4R2-S2, 22.4R3;
  • 23.2 versions earlier than 23.2R1-S1, 23.2R2.

This issue does not affect Juniper Networks Junos OS 21.4R1 and later versions of 21.4.

AnalysisAI

An Exposure of Resource to Wrong Sphere vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on SRX 300 Series allows an unauthenticated, adjacent attacker to cause a. Rated high severity (CVSS 7.1), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Exposure of Resource to Wrong Sphere (CWE-668), which allows attackers to access resources from an unintended security context. An Exposure of Resource to Wrong Sphere vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on SRX 300 Series allows an unauthenticated, adjacent attacker to cause a Denial of Service (DoS). Specific valid link-local traffic is not blocked on ports in STP blocked state but is instead sent to the control plane of the device. This leads to excessive resource consumption and in turn severe impact on all control and management protocols of the device.2 version 21.2R3-S3 and later versions earlier than 21.2R3-S6; * 22.1 version 22.1R3 and later versions earlier than 22.1R3-S4; * 22.2 version 22.2R2 and later versions earlier than 22.2R3-S2; * 22.3 version 22.3R2 and later versions earlier than 22.3R3-S1; * 22.4 versions earlier than 22.4R2-S2, 22.4R3; * 23.2 versions earlier than 23.2R1-S1, 23.2R2. This issue does not affect Juniper Networks Junos OS 21.4R1 and later versions of 21.4. Affected products include: Juniper Junos. Version information: version 21.2.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Implement proper access controls, validate resource access permissions, use security boundaries.

More in Junos

View all
CVE-2016-1285 MEDIUM
6.8 Mar 09

named in ISC BIND 9.x before 9.9.8-P4 and 9.10.x before 9.10.3-P4 does not properly handle DNAME records when parsing fe

CVE-2016-1286 HIGH
8.6 Mar 09

named in ISC BIND 9.x before 9.9.8-P4 and 9.10.x before 9.10.3-P4 allows remote attackers to cause a denial of service (

CVE-2023-36845 CRITICAL POC
9.8 Aug 17

A PHP External Variable Modification vulnerability in J-Web of Juniper Networks Junos OS on EX Series and SRX Series all

CVE-2013-6618 CRITICAL POC
9.0 Nov 05

jsdm/ajax/port.php in J-Web in Juniper Junos before 10.4R13, 11.4 before 11.4R7, 12.1 before 12.1R5, 12.2 before 12.2R3,

CVE-2014-6380 HIGH POC
7.8 Oct 14

Juniper Junos 11.4 before R11, 12.1 before R9, 12.1X44 before D30, 12.1X45 before D20, 12.1X46 before D15, 12.1X47 befor

CVE-2021-0253 HIGH POC
7.8 Apr 22

NFX Series devices using Juniper Networks Junos OS are susceptible to a local command execution vulnerability thereby al

CVE-2021-0252 HIGH POC
7.8 Apr 22

NFX Series devices using Juniper Networks Junos OS are susceptible to a local code execution vulnerability thereby allow

CVE-2019-0053 HIGH POC
7.8 Jul 11

Insufficient validation of environment variables in the telnet client supplied in Junos OS can lead to stack-based buffe

CVE-2023-22415 HIGH POC
7.5 Jan 13

An Out-of-Bounds Write vulnerability in the H.323 ALG of Juniper Networks Junos OS allows an unauthenticated, network-ba

CVE-2022-22223 HIGH POC
7.5 Oct 18

On QFX10000 Series devices using Juniper Networks Junos OS when configured as transit IP/MPLS penultimate hop popping (P

CVE-2022-22209 HIGH POC
7.5 Jul 20

A Missing Release of Memory after Effective Lifetime vulnerability in the kernel of Juniper Networks Junos OS allows an

CVE-2022-22188 HIGH POC
7.5 Apr 14

An Uncontrolled Memory Allocation vulnerability leading to a Heap-based Buffer Overflow in the packet forwarding engine

Share

CVE-2024-21605 vulnerability details – vuln.today