Skip to main content

CVE-2024-10476

HIGH
Use of Default Credentials (CWE-1392)
2024-12-17 cybersecurity@bd.com
8.0
CVSS 3.1 · Vendor: bd
Share

Severity by source

Vendor (bd) PRIMARY
8.0 HIGH
AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from Vendor (bd) · only source for this CVE.

CVSS VectorVendor: bd

CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Adjacent
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Dec 17, 2024 - 16:15 cve.org
HIGH 8.0

DescriptionCVE.org

Default credentials are used in the above listed BD Diagnostic Solutions products. If exploited, threat actors may be able to access, modify or delete data, including sensitive information such as protected health information (PHI) and personally identifiable information (PII). Exploitation of this vulnerability may allow an attacker to shut down or otherwise impact the availability of the system. Note: BD Synapsys™ Informatics Solution is only in scope of this vulnerability when installed on a NUC server. BD Synapsys™ Informatics Solution installed on a customer-provided virtual machine or on the BD Kiestra™ SCU hardware is not in scope.

AnalysisAI

Default credentials are used in the above listed BD Diagnostic Solutions products. Rated high severity (CVSS 8.0), this vulnerability is low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Use of Default Credentials (CWE-1392), which allows attackers to gain access using factory-default usernames and passwords. Default credentials are used in the above listed BD Diagnostic Solutions products. If exploited, threat actors may be able to access, modify or delete data, including sensitive information such as protected health information (PHI) and personally identifiable information (PII). Exploitation of this vulnerability may allow an attacker to shut down or otherwise impact the availability of the system. Note: BD Synapsys™ Informatics Solution is only in scope of this vulnerability when installed on a NUC server. BD Synapsys™ Informatics Solution installed on a customer-provided virtual machine or on the BD Kiestra™ SCU hardware is not in scope.

Affected ProductsAI

See vendor advisory for affected versions.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Force credential change on first use, remove default accounts, document required credential changes.