W6 Firmware
CVE-2024-0994
CRITICAL
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been declared as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252259. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
AnalysisAI
A vulnerability was found in Tenda W6 1.0.0.9(4122). Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Technical ContextAI
This vulnerability is classified under CWE-121. A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been declared as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252259. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Affected products include: Tenda W6 Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
More in W6 Firmware
View allA vulnerability was found in Tenda W6 1.0.0.9(4122). Rated critical severity (CVSS 9.8), this vulnerability is remotely
A stack overflow vulnerability exists in /goform/setAutoPing in Tenda W6 V1.0.0.9(4122), which allows an attacker to con
A command injection vulnerability exists in /goform/exeCommand in Tenda W6 V1.0.0.9(4122), which allows attackers to con
A stack overflow vulnerability exists in /goform/WifiMacFilterSet in Tenda W6 V1.0.0.9(4122) version, which can be explo
A stack overflow vulnerability exists in /goform/wifiSSIDset in Tenda W6 V1.0.0.9(4122) version, which can be exploited
A stack overflow vulnerability exists in /goform/WifiMacFilterGet in Tenda W6 V1.0.0.9(4122) version, which can be explo
A stack overflow vulnerability exists in /goform/wifiSSIDget in Tenda W6 V1.0.0.9(4122) version, which can be exploited
Same weakness CWE-121 – Stack-based Buffer Overflow
View allSame technique Buffer Overflow
View allShare
External POC / Exploit Code
Leaving vuln.today