I6 Firmware
CVE-2024-0992
CRITICAL
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
A vulnerability was found in Tenda i6 1.0.0.9(3857) and classified as critical. This issue affects the function formwrlSSIDset of the file /goform/wifiSSIDset of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252257 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
AnalysisAI
A vulnerability was found in Tenda i6 1.0.0.9(3857) and classified as critical. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Technical ContextAI
This vulnerability is classified under CWE-121. A vulnerability was found in Tenda i6 1.0.0.9(3857) and classified as critical. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252257 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Affected products include: Tenda I6 Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
More in I6 Firmware
View allA vulnerability was found in Tenda i6 1.0.0.9(3857). Rated critical severity (CVSS 9.8), this vulnerability is remotely
A vulnerability has been found in Tenda i6 1.0.0.9(3857) and classified as critical. Rated critical severity (CVSS 9.8),
A vulnerability, which was classified as critical, was found in Tenda i6 1.0.0.9(3857). Rated critical severity (CVSS 9.
Tenda i6 V1.0.0.8(3856) is vulnerable to Buffer Overflow via /goform/WifiMacFilterSet. Rated high severity (CVSS 7.5), t
Tenda i6 V1.0.0.8(3856) is vulnerable to Buffer Overflow via /goform/wifiSSIDget. Rated high severity (CVSS 7.5), this v
Same weakness CWE-121 – Stack-based Buffer Overflow
View allSame technique Buffer Overflow
View allShare