Parasolid CVE-2023-38529

HIGH
Out-of-bounds Read (CWE-125)
2023-08-08 productcert@siemens.com
7.3
CVSS 4.0 · Vendor: siemens
View

Vulnerability Assessment

Weakness
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, read limits
MITRE ATT&CK

1 technique across 1 tactic: Collection

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 7.3 (HIGH). Attack characteristics: local attack vector, high complexity, no privileges required, user interaction required.

Exploit ScenarioDerived

A local attacker with access to the system could read data from memory outside the intended buffer boundaries. No authentication is required to exploit this vulnerability.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.184), Teamcenter Visualization. Rated high severity (CVSS 7.3), this vulnerability is no authentication required. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate array indices and buffer lengths. Use memory-safe languages. Enable AddressSanitizer during testing.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as Out-of-bounds Read (CWE-125), which allows attackers to read data from memory outside the intended buffer boundaries. A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.184), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. Affected products include: Siemens Parasolid, Siemens Teamcenter Visualization.

Know when Parasolid gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (siemens) PRIMARY 7.3 HIGH
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (siemens) · only source for this CVE.

CVSS VectorVendor: siemens

Attack Vector
Local
Attack Complexity
High
Attack Requirements
None
Privileges Required
None
User Interaction
Passive
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

DescriptionCVE.org

A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.184), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.

Threat Intelligence Overview

EPSS Score
0.2%
Top 91% exploitable
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.2%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Defer
Exploitation· derived
None
System Exposure· derived
Small
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

36
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +36
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.

Affected Products (CPE)CVE.org

cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*
CVE-2023-25140 HIGH
7.8 Feb 14

A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.254), Parasolid V34.1 (All versions < V34.1

CVE-2024-31980 HIGH
7.8 May 14

A vulnerability has been identified in Parasolid V35.1 (All versions < V35.1.256), Parasolid V36.0 (All versions < V36.0

CVE-2023-45601 HIGH
7.8 Oct 10

A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.262), Parasolid V35.1 (All versions < V35.1

CVE-2023-41033 HIGH
7.8 Sep 12

A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.260), Parasolid V35.1 (All versions < V35.1

CVE-2023-41032 HIGH
7.8 Sep 12

A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0

CVE-2023-30795 HIGH
7.8 Aug 08

A vulnerability has been identified in JT Open (All versions < V11.4), JT Utilities (All versions < V13.4), Parasolid V3

CVE-2022-46349 HIGH
7.8 Dec 13

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0

CVE-2022-46348 HIGH
7.8 Dec 13

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0

CVE-2022-46347 HIGH
7.8 Dec 13

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0

CVE-2022-46346 HIGH
7.8 Dec 13

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0

CVE-2022-46345 HIGH
7.8 Dec 13

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0

CVE-2022-43397 HIGH
7.8 Nov 08

A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1