Rut950 Firmware
CVE-2023-32349
HIGH
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
Lifecycle Timeline
1DescriptionNVD
Version 00.07.03.4 and prior of Teltonika’s RUT router firmware contain a packet dump utility that contains proper validation for filter parameters. However, variables for validation checks are stored in an external configuration file. An authenticated attacker could use an exposed UCI configuration utility to change these variables and enable malicious parameters in the dump utility, which could result in arbitrary code execution.
AnalysisAI
Version 00.07.03.4 and prior of Teltonika’s RUT router firmware contain a packet dump utility that contains proper validation for filter parameters. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified under CWE-15. Version 00.07.03.4 and prior of Teltonika’s RUT router firmware contain a packet dump utility that contains proper validation for filter parameters. However, variables for validation checks are stored in an external configuration file. An authenticated attacker could use an exposed UCI configuration utility to change these variables and enable malicious parameters in the dump utility, which could result in arbitrary code execution. Affected products include: Teltonika-Networks Rut200 Firmware, Teltonika-Networks Rut240 Firmware, Teltonika-Networks Rut241 Firmware, Teltonika-Networks Rut300 Firmware, Teltonika-Networks Rut360 Firmware. Version information: Version 00.07.03.4.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
More in Rut950 Firmware
View allThe management interface for the Teltonika RUT9XX routers (aka LuCI) with firmware 00.03.265 and earlier allows remote a
Teltonika RUT9XX routers with firmware before 00.04.233 are prone to multiple unauthenticated OS command injection vulne
Teltonika RUT9XX routers with firmware before 00.04.233 provide a root terminal on a serial interface without proper acc
Teltonika RUT9XX routers with firmware before 00.05.01.1 are prone to cross-site scripting vulnerabilities in hotspotlog
Versions 00.07.00 through 00.07.03 of Teltonika’s RUT router firmware contain an operating system (OS) command injection