Tecnomatix Plant Simulation
CVE-2023-27402
HIGH
Severity by source
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Primary rating from Vendor (siemens) · only source for this CVE.
CVSS VectorVendor: siemens
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionCVE.org
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20334)
AnalysisAI
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Out-of-bounds Read (CWE-125), which allows attackers to read data from memory outside the intended buffer boundaries. A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20334) Affected products include: Siemens Tecnomatix Plant Simulation.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate array indices and buffer lengths. Use memory-safe languages. Enable AddressSanitizer during testing.
More in Tecnomatix Plant Simulation
View allImproper TLS certificate validation in Siemens Software Center, Simcenter 3D, Simcenter Femap, Simcenter STAR-CCM+, Soli
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant S
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V23
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant S
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant S
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant S
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant S
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant S
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions <
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions <
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions <
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions <
Same weakness CWE-125 – Out-of-bounds Read
View allSame technique Buffer Overflow
View allShare
External POC / Exploit Code
Leaving vuln.today