Skip to main content

Ac6 Firmware CVE-2023-26976

HIGH
Out-of-bounds Write (CWE-787)
2023-04-04 cve@mitre.org
7.5
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, write limits
MITRE ATT&CK

2 techniques across 2 tactics: Execution, Privilege Escalation

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 7.5 (HIGH). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. Public proof-of-concept exploit code is available.

Exploit ScenarioDerived

A remote attacker could write data beyond allocated buffer boundaries leading to code execution or crashes by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability.

This Week Schedule remediation this week. Why: HIGH severity + EPSS > 10%.
No patch listed yet 15.9% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate write boundaries, use memory-safe languages, enable compiler protections (ASLR, stack canaries).

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as Out-of-bounds Write (CWE-787), which allows attackers to write data beyond allocated buffer boundaries leading to code execution or crashes. Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function. Affected products include: Tenda Ac6 Firmware.

Know when Ac6 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 7.5 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

DescriptionNVD

Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.

Threat Intelligence Overview

EPSS Score
15.9%
Top 3% exploitable
Exploit
POC
Public exploit code exists
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC Yes
EPSS 15.9%
Patch available No
Active threat Yes
Deciding rule
HIGH severity + EPSS > 10%
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact· derived
Medium

Priority Score

74
Low Medium High Critical
KEV: 0
EPSS: +16
CVSS: +38
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

Memory corruption occurs when a program writes data beyond the boundaries of allocated memory regions or accesses memory in unintended ways, violating the integrity of the process's address space.

Affected Products (CPE)NVD

cpe:2.3:o:tenda:ac6_firmware:15.03.05.09:*:*:*:*:*:*:*
CVE-2024-52714 CRITICAL POC
9.8 Nov 19

Tenda AC6 v2.0 v15.03.06.50 was discovered to contain a buffer overflow in the function 'fromSetSysTime. Rated critical

CVE-2025-25343 CRITICAL POC
9.8 Feb 12

Tenda AC6 V15.03.05.16 firmware has a buffer overflow vulnerability in the formexeCommand function. Rated critical sever

CVE-2025-29031 CRITICAL POC
9.8 Mar 14

Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the fromAddressNat function. Rated critical sever

CVE-2025-29030 CRITICAL POC
9.8 Mar 14

Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the formWifiWpsOOB function. Rated critical sever

CVE-2025-29029 CRITICAL POC
9.8 Mar 14

Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the formSetSpeedWan function. Rated critical seve

CVE-2023-40838 CRITICAL POC
9.8 Aug 30

Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_3A1D0' contains a command execution vulnerability. Rate

CVE-2023-40846 CRITICAL POC
9.8 Aug 28

Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function sub_90998. Rated critic

CVE-2023-38937 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC

CVE-2023-38936 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28,

CVE-2023-38933 CRITICAL POC
9.8 Aug 07

Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0

CVE-2023-38931 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1

CVE-2023-2923 CRITICAL POC
9.8 May 27

A vulnerability classified as critical was found in Tenda AC6 US_AC6V1.0BR_V15.03.05.19. Rated critical severity (CVSS 9

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy