Infrasuite Device Master
CVE-2023-1144
HIGH
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V8 - Authorization Authorization logic validation
MITRE ATT&CK
1 technique across 1 tactic: Privilege Escalation The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 8.8 (HIGH). Attack characteristics: network attack vector, low complexity, low privileges required, no user interaction not required. |
| Exploit ScenarioDerived | A remote attacker could bypass authorization checks to access restricted resources by sending crafted requests to the affected application. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization,. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Review and test authorization logic, implement consistent access control checks, use centralized authorization framework.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Incorrect Authorization (CWE-863), which allows attackers to bypass authorization checks to access restricted resources. Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization, which could result in privilege escalation. Affected products include: Deltaww Infrasuite Device Master. Version information: prior to 1.0.5.
Know when Infrasuite Device Master gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization, which could result in privilege escalation.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.
Privilege escalation occurs when an attacker leverages flaws in access control mechanisms to gain permissions beyond what they were originally granted.
Affected Products (CPE)NVD
More in Infrasuite Device Master
View allDelta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status se
In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to
In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to
Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an
Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve sy
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verif
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters us
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper aut
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB