Infrasuite Device Master
CVE-2022-41644
HIGH
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges.
AnalysisAI
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. This Missing Authentication for Critical Function vulnerability could allow attackers to access critical functionality without authentication.
Technical ContextAI
This vulnerability is classified as Missing Authentication for Critical Function (CWE-306), which allows attackers to access critical functionality without authentication. Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges. Affected products include: Deltaww Infrasuite Device Master.
RemediationAI
A vendor patch is available. Apply the latest security update as soon as possible. Require authentication for all sensitive operations, implement defense in depth.
More in Infrasuite Device Master
View allDelta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status se
In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to
In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to
Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an
Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve sy
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verif
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters us
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper aut
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through
Same technique Authentication Bypass
View allShare
External POC / Exploit Code
Leaving vuln.today