Skip to main content

Scadapro Server CVE-2022-2892

HIGH
Out-of-bounds Write (CWE-787)
2022-08-31 ics-cert@hq.dhs.gov
7.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
7.8 HIGH
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Attack Vector
Local
Attack Complexity
Low
Privileges Required
None
User Interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Aug 31, 2022 - 21:15 nvd
HIGH 7.8

DescriptionNVD

Measuresoft ScadaPro Server (Versions prior to 6.8.0.1) uses an unmaintained ActiveX control, which may allow an out-of-bounds write condition while processing a specific project file.

AnalysisAI

Measuresoft ScadaPro Server (Versions prior to 6.8.0.1) uses an unmaintained ActiveX control, which may allow an out-of-bounds write condition while processing a specific project file. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity.

Technical ContextAI

This vulnerability is classified as Out-of-bounds Write (CWE-787), which allows attackers to write data beyond allocated buffer boundaries leading to code execution or crashes. Measuresoft ScadaPro Server (Versions prior to 6.8.0.1) uses an unmaintained ActiveX control, which may allow an out-of-bounds write condition while processing a specific project file. Affected products include: Measuresoft Scadapro Server. Version information: prior to 6.8.0.1.

RemediationAI

A vendor patch is available. Apply the latest security update as soon as possible. Validate write boundaries, use memory-safe languages, enable compiler protections (ASLR, stack canaries).

Share

CVE-2022-2892 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy