Simatic Energy Manager Basic
CVE-2022-23450
CRITICAL
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A08:2025 - Software or Data Integrity Failures
ASVS 5.0
V1 - Encoding and Sanitization Safe deserialization, type allowlists
MITRE ATT&CK
2 techniques across 2 tactics: Execution, Initial Access The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 9.8 (CRITICAL). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. |
| Exploit ScenarioDerived | A remote attacker could execute arbitrary code through malicious serialized objects by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Deserialization of Untrusted Data vulnerability could allow attackers to execute arbitrary code through malicious serialized objects.
RemediationAI
A vendor patch is available. Apply the latest security update as soon as possible. Avoid deserializing untrusted data. Use safe serialization formats (JSON). Implement integrity checks and type allowlists.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Deserialization of Untrusted Data (CWE-502), which allows attackers to execute arbitrary code through malicious serialized objects. A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges. Affected products include: Siemens Simatic Energy Manager Basic, Siemens Simatic Energy Manager Pro.
Know when Simatic Energy Manager Basic gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Insecure deserialization occurs when an application converts serialized data (a stream of bytes representing an object's state) back into a living object without proper validation.
Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.
Affected Products (CPE)NVD
More in Simatic Energy Manager Basic
View allA vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manag
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manag
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB