Skip to main content

Dialink CVE-2021-38422

HIGH
Cleartext Storage of Sensitive Information (CWE-312)
2021-11-03 ics-cert@hq.dhs.gov
7.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
7.8 HIGH
AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Local
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Nov 03, 2021 - 20:15 nvd
HIGH 7.8

DescriptionNVD

Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges.

AnalysisAI

Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-312. Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges. Affected products include: Deltaww Dialink.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

CVE-2021-38424 HIGH
7.8 Nov 03

The tag interface of Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to an attacker injecting formula

CVE-2021-38420 HIGH
7.8 Nov 03

Delta Electronics DIALink versions 1.2.4.0 and prior default permissions give extensive permissions to low-privileged us

CVE-2021-38416 HIGH
7.8 Nov 03

Delta Electronics DIALink versions 1.2.4.0 and prior insecurely loads libraries, which may allow an attacker to use DLL

CVE-2022-2660 HIGH
7.5 Dec 13

Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic k

CVE-2022-2969 HIGH
7.5 Dec 01

Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname int

CVE-2021-38418 MEDIUM
5.9 Nov 03

Delta Electronics DIALink versions 1.2.4.0 and prior runs by default on HTTP, which may allow an attacker to be position

CVE-2021-38488 MEDIUM
4.8 Nov 03

Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated atta

CVE-2021-38428 MEDIUM
4.8 Nov 03

Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated atta

CVE-2021-38411 MEDIUM
4.8 Nov 03

Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated atta

CVE-2021-38407 MEDIUM
4.8 Nov 03

Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated atta

CVE-2021-38403 MEDIUM
4.8 Nov 03

Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated atta

CVE-2025-58321 CRITICAL
10.0 Sep 11

Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability. Rated critical severity (CVSS

Share

CVE-2021-38422 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy